HTZ2460/HTZ2460L/CHTZ2460/CHTZ2460L
8. Maintenance
MA11
■PROCEDURES TO BE PERFORMED AFTER EVERY 100 HOURS OF USE
1.Remove the muffler, insert a screwdriver into the vent, and wipe away any carbon buildup. Wipe away any carbon buildup on the muffler exhaust vent and cylinder exhaust port at the same time.
2.Tighten all screws, bolts, and fittings.
3.Check to see if any oil or grease has worked its way in between the clutch lining and drum, and if it has, wipe it away using
■MUFFLER
WARNING
MA12 [HTZ]
MA13 [CHTZ]
•Inspect periodically, the muffler for loose fasteners, any damage or corrosion. If any sign of exhaust leakage is found, stop using the machine and have it repaired immediately.
•Note that failing to do so may result in the engine catching on fire.
■SPARK ARRESTER
•The muffler is equipped with a spark arrester to prevent red hot carbon from flying out of the exhaust outlet. Periodically inspect and clean as necessary with a wire brush.
In the State of California it is required by law (Section 4442 of the California Public Resources Code) to equip a spark arrester when a gas powered tool is used in any forest covered, brush covered, or grass covered unimproved land. (MA12)(MA13)
(1)Bolt
(2)Spark arrester