MAINTENANCE AND TROUBLESHOOTING

Most problems can be solved by following the simple steps below. Find the symptom that applies, and fol- low the steps listed. If further assistance is needed, please see the front cover of this manual.

WEEKLY MAINTENANCE

Inspect and properly tighten all external parts of the el- liptical exerciser. Clean the elliptical exerciser with a small amount of mild multi-purpose cleaner applied to a 100% cotton cloth. When cleaning the elliptical exer- ciser, pay special attention to the track and the wheels. Remove all debris from the track. Clean the pedal cov- ers with a soft nylon brush. Do not use acidic clean- ers. Never spray any cleaner directly onto the ellip- tical exerciser.

TROUBLESHOOTING

1. SYMPTOM: THE ELLIPTICAL EXERCISER IS

NOT LEVEL

If the elliptical exerciser rocks slightly during use,

see HOW TO MOVE AND LEVEL THE ELLIPTICAL

5.SYMPTOM: THE CONSOLE TURNS OFF AS SOON AS YOU STOP PEDALING

If the console turns off as soon as you stop pedal- ing, the battery pack may not be charged. The longer you pedal, the longer the battery pack will re- tain a charge. It may be necessary to pedal for a few minutes to charge the battery pack each time you exercise. If the console turns off as soon as you stop pedaling, even after you have pedaled for sev- eral minutes, call the toll-free telephone number on the front cover of this manual immediately.

6.SYMPTOM: THE PEDALS SLIP DURING USE

If the pedals slip during use, the drive belt is slipping. Follow the instructions below to adjust the tension of the drive belt.

EXERCISER on page 12.

2. SYMPTOM: THE PULSE SENSOR DOES NOT

FUNCTION PROPERLY

If the chest pulse sensor does not function properly,

see CHEST PULSE SENSOR TROUBLESHOOT-

ING on pages 10 and 11.

If the handgrip pulse sensor does not function prop-

erly, see step 5 on page 14.

3. SYMPTOM: THE PEDAL DISKS RUB AGAINST

THE SIDE SHIELDS

If a pedal disk rubs against a side shield, loosen the

side shield mounting screws and move the side

shield slightly until the pedal disk stops rubbing.

Then, retighten the side shield mounting screws.

First, remove the two M6 x 16mm Button Screws (49) attaching the left Pedal Disk (5). Without removing the Pedal Disk, pivot it out of the way.

Next, locate the M10 Flange Nut (95). Turn the Flange Nut clock- wise until the ped- als no longer slip during the power stroke.

5

49

95

4. SYMPTOM: THE PEDAL WHEELS SQUEAK

Reattach the Pedal Disk (5).

If the pedal wheels squeak, use a 100% cotton cloth to remove debris from the track and the wheels. If the pedal wheels continue to squeak, apply a light coat of silicone-based lubricant to the track.

19

Page 19
Image 19
Reebok Fitness RBEL4255.0 manual Maintenance and Troubleshooting