SAFETY LABEL

This is a copy of the label that accompanies each CLASSIC Freestanding Gas Stove - Nat- ural Gas. We have printed a copy of the contents here for your review. The safety label is located on the back panel.

NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.

For the State of Massachusetts, installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of Massachusetts.

For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length.

For the State of Massachusetts, the appli- ances individual manual shut-off must be a t-handle type valve.

FPI Fireplace Products International Ltd.

Delta, BC, Canada

Serial No. 201

Listed: GAS FIRED VENTED ROOM HEATER

Certified for: CANADA and USA Report No. 476-1345-00 (Oct. 1996)

Tested to: ANSI Z21.88b-2003/CSA 2.33b-2003, CAN/CGA-2.17-M91

FACTORY EQUIPPED FOR NATURAL GAS:

Model C33-NG2 Factory Equipped for 0-2000 ft.

Minimum supply pressure

5"

WC/C.E. (1.25Kpa)

Manifold pressure High

3.8"

WC/C.E. (0.94Kpa)

Manifold pressure Low

1.1"

WC/C.E. (0.27Kpa)

Orifice size

36

DMS

 

Altitude

0-2000

ft/pi

(0-610 m)

Maximum Input

33,000

BTUH

(9.67Kw/h)

Minimum Input

17,000

BTUH

(4.98Kw/h)

 

 

 

 

HIGH ALTITUDE CONVERTED NATURAL GAS:

Model C33-NG2

Field Convertable for Altitude 2000-4500 ft. (Report No.476-1345-00)

Minimum supply pressure 5"

WC/C.E. (1.25Kpa)

Manifold pressure High

3.8"

WC/C.E. (0.94Kpa)

Manifold pressure Low

1.1"

WC/C.E. (0.27Kpa)

Orifice size

38

DMS

 

Altitude

2000-4500 ft/pi

(610-1370m)

Maximum Input

29,000

BTUH

(8.5Kw/h)

Minimum Input

15,300

BTUH

(4.48Kw/h)

 

 

 

 

GAS FIRED VENTED ROOM HEATER

This appliance must be installed in accordance

with local codes, if any; If not, follow:

ANSI Z223.1/CAN 1-B149.

Electrical Supply (115 V, 1.13 A, 60 Hz)

Not for use with solid fuel.

Optional Fan: (Part #490-917)

Minimum Clearances to Combustibles

 

Back wall

 

 

 

Back wall

Sidewall

B

 

Sidewall

Sidewall

 

A

A

E

A - 10" B - 6" E - 1.5"

Minimum ceiling height from top of unit: 36"/914mm

DO NOT REMOVE THIS LABEL

Made in Canada

908-634a

4

Regency CLASSIC C33-2 Freestanding Gas Stove

Page 4
Image 4
Regency C33-LP2, C33-NG2 installation manual Safety Label, Delta, BC, Canada