Regency C33-LP2, C33-NG2 Removing Valve Assembly, Installing Valve, Diagram Diagram

Models: C33-LP2 C33-NG2

1 24
Download 24 pages 6.96 Kb
Page 18
Image 18
REMOVING VALVE

MAINTENANCE

REMOVING VALVE

ASSEMBLY

1) Shut off gas supply.

2) If optional fan is installed, disconnect pow- er source to stove.

3) Remove access panel.

a) Front panel on pedestal model. See diagram 1.

b) Panel from bottom of leg shield. See diagram 2.

Note: Access panel only has to be loos- ened to be taken out.

8)If optional fan is installed, remove thermo- disc to bracket by removing three (3) phillips

head M5 screws.

9) Remove front cover with Piezo Igniter by removing two (2) sheet metal screws.

10) Loosen four (4) phillips head M5 valve mounting screws from underside of fire- box. Push valve assembly forward on the teardrop slots and drop down. Diagram 3.

16)Remove inlet pipe with pipe wrench. Note orientation of 90o elbow.

17)Remove two (2) phillips head M5 screws on each side of the valve.

18)Remove valve and remove gas out 90o brass fitting. Note orientation of fitting.

INSTALLING VALVE

Diagram 1

Diagram 2

4)Disconnect gas line to stove.

5)Disconnect 3/8" NPT pipe from 90o elbow on valve.

6 ) Disconnect the two (2) switch wires from valve.

7)Remove two (2) orifice bracket screws inside firebox.

Diagram 3

11)Disconnect Piezo wire.

To remove valve from valve assembly, continue.

12)Remove two (2) thermopile wires.

13)Remove thermocouple with a 9 mm (met- ric) wrench.

14)Remove pilot nut with an 11 mm wrench.

15)Remove valve to orifice nut with a 13/16" wrench.

ASSEMBLY

1)To install a new valve assembly, reverse instructions for removing valve. See assembly steps 1-11.

2)Check for leaks and manifold pressure. See Gas Pressure Test instructions.

3)To reinstall valve, reverse instructions for removing valve assembly, steps 12-18.

18

Regency CLASSIC C33-2 Freestanding Gas Stove

Page 18
Image 18
Regency C33-LP2, C33-NG2 installation manual Removing Valve Assembly, Installing Valve, Diagram Diagram