LOG REPLACEMENT

MAINTENANCE

LOG REPLACEMENT

The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door to carefully re- move the logs. The pilot light generates enough heat to burn someone.

If for any reason a log should need replace- ment, use only Regency replacement logs. The position of these logs must be as shown in the diagram under Log Installation.

NOTE: Improper positioning of logs may create carbon build-up and will alter the unit’s performance which is not covered under war- ranty.

GOLD-PLATED DOORS

The 24 carat gold plated finish on the door requires little maintenance, and need only be cleaned with a damp cloth. DO NOT use abrasive materials or chemical cleaners, as they may harm the finish and void the warran- ty. Clean any fingerprints off before turning the unit on.

GLASS

REPLACEMENT

Your CLASSIC stove is supplied with high temperature, 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce. In the event that you break your glass by impact, purchase your replace- ment glass from an authorized Regency dealer only, and follow our step-by-step instructions for replacement.

1)Allow the stove to cool before removing or replacing glass.

2)To remove the door from the stove remove the securing screw located between the ashlip and the door, then unfasten the latch.

3)Remove gold hinge caps from door.

4)Lift door off hinge.

5)Lay door on a soft, flat surface.

6)Remove the screws in the glass retainer clips and remove the glass retainer rod. Remove any remaining pieces of glass and ensure that the door is free of debris. Use caution when removing broken glass to avoid injury.

7)Install the replacement glass. When placing the replacement glass in the door, make sure that the glass gasketing will properly seal your unit.

8)Put glass in place and then position glass retainer rod.

Note: Do not use substitute materials. If your glass does break, do not continue to use your unit until it has been replaced.

9)Position the glass retainer clips and door securing bracket. Secure the glass retain- ing screws but do not overtighten as this may cause the glass to break after the unit heats up.

10)Tighten all screws evenly.

Note: Do not overtighten as this may cause breakage.

11)Slip door over hinge pins.

12)Put hinge caps back onto door.

13)Close door and secure the security bracket with the screw.