Regency E33S Installation, Optional Wall Thermostat, Optional Remote, Control, to the 120V wires

Models: E33S

1 32
Download 32 pages 6.75 Kb
Page 16
Image 16
OPTIONAL REMOTE

INSTALLATION

INSTALLATION

For PROPANE Units and Units Equipped with DC Spark Boxes*

*For installation of the DC Spark Box refer to the LP Conversion instructions in this manual.

OPTIONAL REMOTE

3) Install 3AAAalkaline batteries in transmitter

 

CONTROL

and 4 AA alkaline batteries in the receiver.

Install the receiver and its cover in the wall.

 

Switch the remote receiver to "remote"

Use the FPI Remote Control Kit approved for

mode. The remote control is now ready

for operation. Refer to Remote manual for

this unit. Use of other systems may void your

complete details.

warranty.

 

It is recommended that the thermostat be installed on an interior wall.

CAUTION

Do not connect the millivolt
wall thermostat wires

to the 120V wires.

The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate.

1)Choose a convenient location on the wall to install the receiver and the receptacle box (protection from extreme heat is very important). Run wires from the fireplace to that location. Use Thermostat Wire Table.

2)Connect the wires as per the wiring diagrams below.

CAUTION

Do not connect the millivolt

remote control wires

to the 120V wires.

 

T

O

 

 

 

 

O

N

I

 

TH

To wall switch,

 

 

 

P

 

 

H

 

I

 

 

 

 

L

 

 

 

 

 

 

 

F

 

 

 

 

remote control

 

FO

 

 

OL

TP

 

 

 

 

 

or thermostat

 

 

 

 

 

 

 

 

 

 

THTP

 

 

 

 

 

 

 

To thermopile

OPTIONAL WALL

THERMOSTAT

A wall thermostat may be installed if desired, follow the wiring diagram. Note: the wires are connected to the "TH" on the gas valve. Use the table below to determine the maximum wire length. FPI offers an optional programmable thermostat but any 250-750 millivolt rated non- anticipator type thermostat that is CSA, ULC or UL approved may be used.

Thermostat Wire Table

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire SizeMax. Length

 

 

14 GA.50 Ft.

 

 

16 GA.32 Ft.

 

 

18 GA.20 Ft.

 

 

20 GA.12 Ft.

 

 

22 GA.9 Ft.

 

 