Regency E33S Installation, Minimum Clearances To Combustibles, Combustible Mantel Clearances

Models: E33S

1 32
Download 32 pages 6.75 Kb
Page 9
Image 9
MINIMUM CLEARANCES TO COMBUSTIBLES

INSTALLATION

MINIMUM CLEARANCES TO COMBUSTIBLES

 

From Unit

Side Walls
A* 8" (203 mm)
Ceiling

B

47" (1194 mm)
Min. Mantel Height

C

15" (381 mm)
Max. Mantel Depth

D

3-1/2" (89 mm)
Alcove Width

E

76" (1930 mm)
Alcove Depth

F

36" (914 mm)

*Alcove side wall must have a min. of 8" clearance on one side.

COMBUSTIBLE MANTEL CLEARANCES

INSTALLATION

Due to the extreme heat this fireplace emits, the mantel clearances are critical.

Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non- combustible board.

Mantel can be installed anywhere in shaded area or higher using the above scale.

Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour.

Regency® E33S-1 Sunrise Gas Insert

9

Page 9
Image 9
Regency E33S Installation, Minimum Clearances To Combustibles, Combustible Mantel Clearances, From Unit, Side Walls