MAINTENANCE
9) Remove the base cover by lifting up from the back and maneover 11) Remove the valve tray by undoing the 17 screws. out.
Base Cover | 12) Slighty lift out valve tray. |
10)Disconnect the ON/OFF connector wires from the valve.
NOTE: For LP units disconnect the DC Sparker ignitor wire from the valve.
13) Disconnect the inlet gas line.
14) Replace valve and reverse steps.
ON/OFF Wires
MAINTENANCE
Regency® | 25 |