Regency FG37-LPG, FG37-NG Residential And Manufactured Homes, Mobile Homes Installations

Models: FG37-NG FG37-LPG

1 32
Download 32 pages 56.78 Kb
Page 10
Image 10
RESIDENTIAL AND MANUFACTURED HOMES/
Diagram 1

INSTALLATION

RESIDENTIAL AND MANUFACTURED HOMES/

MOBILE HOMES INSTALLATIONS

You will require the following components with your new Regency Rear Flued Room Sealed Freestanding Gas Stove. Please review your product to make sure you have everything you need. In the event that you are missing any part, contact your dealer.

Note: These are the minimum pieces required.

Other parts may be required for your particular installation.

Minimum components for a Horizontal Installation:

946-110 Horizontal Termination Kit which includes:

1946-201 6-5/8" dia. x 18" (168mm dia. x 457mm) Black Pipe

1946-207 4" dia. x 18" (102mm dia. x 457mm) Aluminum Flue

1946-584 Astro Riser Vent Terminal

1946-202 Wall Penetration Heat Shield for Heat Sensitive walls

 

 

(Wall Thimble) (2 pcs)

1

640-545

Decorative Wall Trim (Black)

1

948-128

Tube Mill-Pac

 

 

Screws

Optional Components:

 

946-204

45o Elbow - 6-5/8" (168mm) Black pipe

 

and 4" (102mm) Aluminum Flue

946-205

Vinyl Siding Shield for Riser Vent

 

Terminal

 

946-208/P

Flue Guard

 

940

Square Wall Thimble Cover*

942Wall Penetration Heat Shield*

* Simpson Dura-Vent components

HORIZONTAL INSTALLATIONS

1)Set the unit in its desired location. Check to determine if wall studs are in the way when the fluing system is attached. If this is the case, you may want to adjust the location of the unit.

2)Assemble the desired combination of pipe and elbow to the appliance adapter with pipe seams oriented down. Offset the pipe seams as double seams in one place will cause the outer pipe to take an oval shape. Kit comes complete with 18" (457mm) of straight flue - 6-5/8" (168mm) dia. black outer pipe and 4" (102mm) dia. inner flue.

3)With the pipe attached to the stove, slide the stove into its correct location, and mark the wall for a 9-1/2" (241mm) (inside dimen- sions) round hole. The center of the round hole should line up with the centerline of the horizontal pipe, as shown in diagram 1. Cut and frame the 9-1/2 (241mm) round hole in the exterior wall where the flue will be terminated. If the wall being penetrated is constructed of non-combustible material, i.e. masonry block or concrete, a 7" (178mm) diameter hole is acceptable.

Note:

a)The horizontal run of flue should have a 1/4 inch (6mm) rise for every 1 foot (305mm) of run towards the termina- tion. Never allow the flue to run down- ward. This could cause high tempera- tures and may present the possibility of a fire.

b)The location of the horizontal flue termi- nation on an exterior wall must meet all local and national building codes, and must not be blocked or obstructed. For External Flue Terminal Locations, see diagram on page 7.

c)Snorkel Terminations:

For installations requiring a vertical rise on the exterior of the building, Astro Riser Vent Terminations as shown in Dia. 2 is available. Follow the same installation procedures as used for standard Horizontal Termination.

NEVER install the Astro Riser vent up- side down.

Diagram 2

*Dia 2: Local codes or regulations may require different clearances.

10

FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater