INSTALLATION
FLUING
The Regency Room Sealed System (Horizontal Termination Kit
The Horiz. Termination Kit
IMPORTANT
Read all instructions carefully before starting the installation. Failure to follow these instruc- tions may create a fire or other safety hazard, and will void the warranty. Be sure to check the fluing and clearance to combustible require- ments on pages 6 to 9. Consult your local building codes before beginning installation.
The location of the termination cap must con- form to the requirements in the Exterior Flue Terminal Locations diagram on page 7.
FLUING
INSTALLATION
PRECAUTIONS
The Regency Room Sealed System and the Vertical Termination with the
1)Installation of any damaged Room Sealed component
2)Unauthorized modification of the Room Sealed System
3)Installation of any component part not man- ufactured or approved by Regency Indus- tries Ltd.
4)Installation other than as instructed by Re- gency Industries Ltd.
Warning: Always maintain required clearances (air spaces) to nearby combustibles to prevent a fire haz- ard. Do not fill air spaces with insu- lation.
The minimum clearance requirements between the outer wall of the flue pipe and nearby combustible surfaces is 30mm. Be sure to check the flue termination clearance require- ments from decks, windows, soffits, gas reg- ulators, air supply inlets and public walkways as specified on page 7 and in your local building codes.
The gas appliance and flue system must be flued directly to the outside of the building, and never be at- tached to a chimney serving a sep- arate solid fuel or
Each Room Sealed gas appliance must use its own separate flue system. Common flue sys- tems are prohibited.
SAFETY
PRECAUTIONS FOR
THE INSTALLER
1)Wear gloves and safety glasses for pro- tection.
2)Exercise extreme caution when using lad- ders or on roof tops.
3)Be aware of electrical wiring locations in walls and ceilings.
PLANNING YOUR FLUING INSTALLATION
See page 7 for Exterior Flue Termination requirements.
When planning your installation, it will be nec- essary to select the proper length of flue pipe for your particular requirements. Determine the minimum clearance to combustibles from the rear of the unit to the wall. It is also important to note the wall thickness. Before cutting the flue hole through the wall ensure that ALL flue and termination clearances (see page 7) will be met.
NOTE: Ensure compliance with the outside flue terminal location before cutting hole as both dimensions must be met.
*If this is an outside corner, the minimum distance between the flue and the outside corner is 12" (30cm). See "F" on the diagram on page 7.
For corner installation, Restrictor must | For straight rear installation, Restric- |
be set at | tor must be set at |
8 | FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater |