Regency FG37-LPG, FG37-NG Installation Checklist, Locating Your Regency Gas Stove

Models: FG37-NG FG37-LPG

1 32
Download 32 pages 56.78 Kb
Page 6
Image 6
INSTALLATION

INSTALLATION

14)Under no circumstances should any solid fuels (wood, paper, cardboard, coal, etc.) be used in this appliance.

15)The appliance area must be kept clear and free of combustible materials, (gases and other flammable vapours and liquids).

INSTALLATION

CHECKLIST

1)

Check Clearances to Combustibles (page

 

6), location of unit (page 6) and fluing

 

requirements (pages 6-9).

2)

Install fluing: Check all fluing requirements,

 

pages 8-12.

3)

Make gas connections, page 12. Test the

 

pilot. Must be as per diagram, pages 15 &

 

22.

4)

If necessary, convert from NG to LPG (page

 

13).

5)

Install log set, page 15.

6)

Install Front Door Front, page 16.

7)

Test Gas Pressure, page 17.

8)

Install Louvres, page 17.

9)

Install optional Remote Control, page 18.

LOCATING YOUR

REGENCY GAS STOVE

When selecting a location for your stove, en- sure that the clearances listed above are met as well as ensuring that there is adequate acces- sibility for servicing and proper operation.

For Flu Termination requirements, see page 7.

This appliance is Listed for bedroom installa- tions when used with a Listed Millivolt Thermo- stat. Some areas may have further require- ments, check local codes before installation.

This appliance is Listed for Alcove installations, maintain minimum Alcove clearances as fol- lows, minimum ceiling height of 1.7m, minimum width of 1.0m and a maximum depth of 0.9m.

Use the minimum clearances shown in the diagrams below:

FG37-NG & FG37-LPG Clearances

A Side Wall to Unit

190 mm

B Back Wall to Unit

76 mm

E Side Wall to Unit

114 mm

FG37-NG & FG37-LPG

Reference Dimensions C Floor to Flue Centerline 635 mm

D Side Wall to Flue Centerline 521 mm

10) Final check, page 18.

Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly and operation fully explained to customer.

This includes:

1) Clocking the appliance to ensure the cor-

rect firing rate (rate noted on label) after

A)Cross Corner

B)Flush with Wall/Alcove

C)Flat on Wall Corner

D)Flat on Wall

CLEARANCES TO COMBUSTIBLES

Minimum ceiling height is 914 mm from top of unit.

burning appliance for 15 minutes.

2) If required, adjusting the primary air to

ensure that the flame does not carbon. First

allow the unit to burn for 15-20 min. to

stabilize.

CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibil- ity of the manufacturer.

The clearances listed are MINIMUM distances. Measure the clearance to both the appliance and the chimney connector. The farthest distance is correct if the two clearances do not coincide. For example, if the appliance is set as indicated in one of the diagrams but the connector is too close, move the stove until the correct clearance to the connector is obtained.

This appliance may be installed only with the clearances as shown in the situations pictured.

Do not combine clearances from one type of installation with another in order to achieve closer clearances.

This unit can be installed on a solid combustible surface like a wood floor. This unit can also be installed directly on carpeting or vinyl when the bottom pedestal cover plate (provided with unit) is installed.

COMBUSTION AND VENTILATION AIR

The combustion air from this appliance is drawn from outside the building through the outer flue.

Extra provision for combustion air inside the room is not required.

6

FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater

Page 6
Image 6
Regency FG37-LPG, FG37-NG Installation Checklist, Locating Your Regency Gas Stove, Clearances To Combustibles