Regency FG37-NG, FG37-LPG installation manual Conversion Kit for NG to LPG Model #516-969

Models: FG37-NG FG37-LPG

1 32
Download 32 pages 56.78 Kb
Page 13
Image 13
Conversion Kit for NG to LPG Model #516-969

INSTALLATION

Conversion Kit for NG to LPG Model #516-969

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!

Conversion Kit 516-969 Contains:

Qty. Part # Description

1904-390 Burner Orifice #52

1908-528 Red "LPG" label

2918-590 Label "Converted to LPG"

1 918-334 Instruction Sheet

1 910-920 Pilot Orifice

1)Shut off the gas supply and unplug the power cord.

2)Open the front door and carefully remove the logs and lava rock.

3)Remove burner.

4)Remove burner orifice with a 1/2" (13mm) wrench and discard. Use a wrench to hold on to the elbow behind the orifice.

5)Reinstall new burner orifice LPG stamped #52 and tighten.

Burner Orifice

6)Remove the 2 screws which hold the pilot.

7)Lift the pilot assembly and remove the pilot tube using an 11mm wrench.

Antenna Manual background

Control Box

Cover

17) Remove the jumper using a plier.

Pilot

Pilot

Pilot

Orifice

Extrusion

Assembly

 

Tube

 

8)Remove the NG orifice and replace it with the LPG orifice.

9) Install the pilot tube to the pilot assembly.

 

Jumper Location

10) Place the pilot assembly over the pilot extru-

 

 

 

sion tube and secure it with 2 screws.

 

 

 

11) Adjust the burner areation setting to fully

 

 

 

 

 

 

 

 

 

open and install the burner.

 

 

 

 

 

 

 

12) Remove the pedestal back cover by remov-

Jumper

 

 

 

ing the 4 Philips screws.

 

 

 

Pilot Tube

13)Stick the conversion label "This unit has been converted to LPG" over top of the serial number decal.

14)Replace the yellow "NG" label with the red "LPG" label.

15)Carefully pull out the control box.

Note: The control box is held in place by velcro.

16)Remove the control box cover by undoing the 3 screws. Maneuver through antenna.

18)Stick the conversion label "This unit has been converted to LPG" on the control box cover.

19)Reverse steps 16, 15 & 12.

20)Open the bottom door and remove the front panel by undoing the 6 screws.

FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater

13

Page 13
Image 13
Regency FG37-NG, FG37-LPG installation manual Conversion Kit for NG to LPG Model #516-969