Regency P36-NG4 FPI Direct Vent System Flex, Snorkel Terminations, Gas Fireplaces, 4 102mm, 6-7/8

Models: P36-NG4 P36D-LP1 P36-LP4 P36D-NG1

1 8
Download 8 pages 39.45 Kb
Page 3
Image 3
FPI Direct Vent System (Flex)

Gas Fireplaces

FPI Direct Vent System (Flex)

Horizontal Terminations Only

These venting systems, in combination with the P36 / P36D Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram.

FPI Direct Vent (Flex) System Termination Kits include all the parts needed to install the P36 / P36D using a flexible vent.

FPI Kit #

Length

Contains:

#946-515

4 Feet

1)

6-5/8” fl exible liner (Kit length)

 

 

2)

4” fl exible liner (Kit length)

 

 

3)

spring spacers (3)

 

 

4)

thimble (2)

 

 

5)

AstroCap termination cap (1)

#946-516

10 Feet

6)

screws (12)

 

 

7)

tube of Mill Pac (1)

 

 

8)

plated screws (8)

 

 

9)

S.S. screws #8 x 1-1/2” drill point, (4)

Notes:

1)Liner sections should be continuous without any joints or seams.

2)Only Flex pipe purchased from Regency may be used for Flex installations.

3)Horizontal sections must be supported every 3 feet.

Wall Thimble (2 pc)

4" (102mm)

AstroCap

dia. flue pipe

Termination Cap

6-7/8"

Part #946-523/P

 

(173mm) dia.

spring

Alternate Horizontal

Flue pipe

spacer

Termination Caps

 

Alternate:

Horizontal

Riser Vent

Terminal

Part# 640-530/P

If required by the external termination location the listed alternate termination caps may be used. (Refer to Page 11)

June 2007 Regency Product Specifications Book

P36 - P36D Gas Fireplace

Snorkel Terminations

Snorkel Terminations:

For installations requiring a vertical rise on the exterior of the building, 14-inch and 36-inch tall Snorkel Terminations and the Riser Vent are available. Follow the same installation procedures as used for standard Horizontal Termination. NEVER install the snorkel upside down.

Below Grade Snorkel Installation (Dura-Vent Only)

If the Snorkel Termination must be installed below grade, i.e. basement application, proper drainage must be provided to prevent water from entering the Snorkel Termination. Refer to Rigid Pipe Installation instructions for details. Do not attempt to enclose the Snorkel within the wall, or any other type of enclosure.

37

Gas Fireplaces

Page 3
Image 3
Regency P36-NG4 FPI Direct Vent System Flex, Snorkel Terminations, Gas Fireplaces, Wall Thimble 2 pc, 4 102mm, AstroCap