Regency P36-LP4 Venting Arrangements - Horizontal Terminations, Gas Fireplaces, P36D ONLY

Models: P36-NG4 P36D-LP1 P36-LP4 P36D-NG1

1 8
Download 8 pages 39.45 Kb
Page 6
Image 6
Venting Arrangements - Horizontal

Gas Fireplaces

Gas Fireplaces

P36 - P36D Gas Fireplace

Venting Arrangements - Horizontal

Terminations

This diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90º elbow (two 45º elbows equal one 90º elbow).

The lightly shaded area,

, in the diagram shows allowable

combinations when installing a P36

The darker shaded area,

, in the diagram shows additional allowable

combinations when installing a P36D.

Note: Must use optional flue adapter (Part # 510-994) when using Rigid Pipe.

Maintain clearances to combustibles.

Horizontal vent must be supported every 3 feet.

Firestops are required at each fl oor level and whenever passing through a wall.

A vent guard may be required as per local codes, refer to page 11 for “Exterior Vent Termination Locations”.

Note: FPI Direct Vent System (Flex) is only approved for horizontal terminations.

Vertical Height (Feet)

0

18

16

14

12

10

8

6

4

2

0

Horizontal (Feet)

2

4

6

8

10

12

14

16

18

20

P36D ONLY

40-1/2" (1029mm) Minimum Height Requirement

Please refer to Page 11 (Exterior Vent Terminations)

for additional guidelines on vent locations.

40

June 2007 Regency Product Specifications Book

Page 6