Regency P36D-LP1 Vertical Venting with Two 2 90 Elbows, Vertical Venting with Three 3 90 Elbows

Models: P36-NG4 P36D-LP1 P36-LP4 P36D-NG1

1 8
Download 8 pages 39.45 Kb
Page 5
Image 5
Vertical Venting

Gas Fireplaces

Vertical Venting

with Two (2) 90° Elbows

Two 45° elbows = One 90° elbow

Option

V

H

V+ V1

Maximum total pipe: length, of

 

 

 

 

all sections, must not exceed

A)

0’ Min.

2’ Max.

1’ Min.

30 feet.

 

 

 

 

B)

1’ Min.

4’ Max.

3’ Min.

Total horizontal sections must

 

 

 

 

not exceed 8 feet.

C)

2’ Min.

5’ Max.

4’ Min.

Minimum of 1 foot between

 

 

 

 

D)

3’ Min.

6’ Max.

5’ Min.

90° elbows is required.

E)

4’ Min.

7’ Max.

6’ Min.

 

 

 

 

 

 

F)

5’ Min.

8’ Max.

7’ Min.

 

Vertical Venting

with Three (3) 90° Elbows

Two 45° elbows = One 90° elbow

Option

V

H + H1

V+ V1

Maximum total pipe: length, of

 

 

 

 

all sections, must not exceed

A)

0’ Min.

2’ Max.

2’ Min.

30 feet.

 

 

 

 

B)

1’ Min.

2’ Max.

3’ Min.

Total horizontal sections must

 

 

 

 

not exceed 8 feet.

C)

2’ Min.

3’ Max.

4’ Min.

Minimum of 1 foot between

D)

3’ Min.

4’ Max.

6’ Min.

90° elbows is required.

 

 

 

 

 

E)

4’ Min.

5’ Max.

7’ Min.

 

F)

5’ Min.

6’ Max.

8’ Min.

 

 

 

 

 

 

G)

6’ Min.

7’ Max.

9’ Min.

 

H)

7’ Min.

8’ Max.

10’ Min.

 

 

 

 

 

 

June 2007 Regency Product Specifications Book

P36 - P36D Gas Fireplace

Gas Fireplaces

39

Page 5
Image 5
Regency P36D-LP1, P36D-NG1 Vertical Venting with Two 2 90 Elbows, Vertical Venting with Three 3 90 Elbows, Gas Fireplaces