INSTALLATION
Diagram 3
STANDARD
FLUSH DOOR
The standard flush door comes with a black frame. To install the frame, simply hook the top door flange onto the top of the unit and swing the door towards the unit, diagram 6. Be careful that the glass gasket does not roll up; there must
be a gap between the gasket and the door lip to ensure
that the door sits securely on the unit. Diagram 7.
OPTIONAL FLUSH TRIM
Attach 2 round magnets to the back of the top trim piece and the other 2 to the bottom trim piece, then attach trim to the top and bottom of Flush door.
9)Attach the brass trim to the faceplate by drilling a 1/8" hole through into the faceplate using the hole in the trim as a guide. Fasten the trim to the faceplate panels using the plated screws. Diagram 4.
Diagram 6
FLUSH LOUVERS
1) The top louver is held in place by friction fit, if the louver needs to be adjusted; bend the bracket out as shown in the diagram.
Diagram 4
10)Attach the faceplate panels to the insert body using the 4 remaining black screws. Diagram 5.
Diagram 5
11)Push the Regency logo plate into the two holes in the bottom left corner of the faceplate. See Diagram 4.
Diagram 7
Use the hook to pull the spring out until you can put the hook into the slot on the bottom door bracket. Repeat for 2nd spring. See diagram 8.
Diagram 8
To remove the flush door, reverse the above steps.
NOTE: The chain must rest on TOP of the gas inlet pipe never under it.
2)Install the Spring Hinges on the left and right side of the bottom of the Firebox using 2 screws per hinge.
3)Place the Bottom Louver near the hinge. Flip hinge over the Bottom Louver and secure using 3 screws.
Hinge
Location
Bottom Louver
12 | U35 FPI Direct Vent Gas Insert |