INSTALLATION
GAS CONNECTION
GAS CONNECTION WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance.
1)If the appliance is to be installed into an existing chimney system, thoroughly clean the masonry or factory built fireplace.
2)The appliance is provided with an opening on the left hand side of the control compartment. A 3/8" NPT gas supply pipe must be brought near this inlet hole.
3)Locate the center point where the vent will pass through the chimney above the appliance. Move the appliance into the exact location where it is to be installed. Ensure that the Insert is level.
VENTING
THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE.
This appliance is designed to be attached to two 3" (76mm)
Masonry chimneys may take various contours which the flexible liner will accommodate. However, keep the flexible liner as straight as possible, avoid unnecessary bending.
Part # | Description |
3" Flex - 35 ft. | |
| Termination Cap |
Alternate Approved Caps | |
980 | Vertical Termination Cap |
991 | High Wind Cap |
923GK | 3" |
flashing |
|
In areas of consistently high winds, we recommend using the Simpson
The Air Intake pipe must be attached to the inlet air collar of the termination cap.
5) Install flashing.
6) Insert both liners into chimney, passing through the damper opening.
7) Install termination cap.
8) Connect the marked end of the liner to the exhaust collar of the vent connector plate marked with an "E", seal connection with high temperature silicone. Secure with gear clamp.
9) Connect the 2nd liner to the intake collar marked with an "I", seal connection with high temperature silicone. Secure with gear clamp.
FLUE LINER
INSTALLATION
1) Cut the flex liner as required.
2)Mark the end of one liner with an "E" to indicate exhaust.
3) Connect the other end of the above liner to the exhaust side of the termination adaptor, seal connection with high temperature silicone. Secure with gear clamp.
4) Connect the 2nd liner to the inlet side of | NOTE: 1) Final gas connection should be | ||||
made after unit is in place to avoid | |||||
the adaptor, | seal connection | with | high | ||
damage to line when pushing the unit | |||||
temperature | silicone. Secure | with | gear | ||
into position. | |||||
clamp. |
|
|
| ||
|
|
|
|
2)
U35 FPI Direct Vent Gas Insert | 9 |
|