Regency U35-NG1, U35-LP1 Final Check, Operating Instructions, First Fire, Lighting Procedure

Models: U35-NG1 U35-LP1

1 32
Download 32 pages 26.72 Kb
Page 20
Image 20
Thermostat Wire Table

OPERATING INSTRUCTIONS

Thermostat Wire Table

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size

Max. Length

14 GA.

50

Ft.

16 GA.

32

Ft.

18 GA.

20

Ft.

20 GA.

12

Ft.

22 GA.

9

Ft.

FINAL CHECK

DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE.

During the first few fires, a white film may develop on the glass front as part of the curing process. The glass should be cleaned or the film will bake on and become very difficult to remove. Use a non-abrasive cleaner and NEVER clean the glass while it is hot.

OPERATING

INSTRUCTIONS

IMPORTANT: Gas on/off knob cannot be turned from "PILOT" to "OFF" unless it is partially depressed.

1)

Turn burner OFF using "ON/OFF" switch.

2)

Turn gas control knob so indicator points

 

to "OFF" position and allow 5 minutes for

 

any gas in the combustion chamber to

 

escape.

3)

Turn gas control knob counterclockwise

 

so indicator points to the "PILOT" position.

 

Depress the gas control knob fully. Depress

 

the ignitor button several times until the

 

pilot lights. After approximately one minute,

 

release the gas control knob. The pilot flame

 

should continue to burn. If the pilot does

Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly. This includes:

1)Clocking the appliance to ensure the correct firing rate (rate noted on label) at 15 minutes.

2)If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15 min. to stabilize.

3)Check for proper draft.

CAUTION

Any alteration to the product that causes sooting or carboning that results in damage to the exterior facia is not the responsibility of

FIRST FIRE

The first fire in your insert is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your fireplace for at least four (4) hours the first time you use it with the fan on. When first operated, the unit will release an odour caused by the curing of the paint, the burning off of any oils remaining from manufacturing. Smoke detectors in the house may go off at this time. Open a few windows to ventilate the room for a couple of hours.

The glass panel may require cleaning after the unit has cooled down.

DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT.

Note: When the glass is cold and the appliance is lit, it may cause condensation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up.

1)Read and understand these instructions before operating this appliance.

2)Check to see that all wiring is correct and enclosed to prevent possible shock.

3)Check to ensure there are no gas leaks.

4)Make sure the glass in the door frame is properly positioned. Never operate the appliance with the glass removed.

5)Verify that the venting and cap are unobstructed.

6)Ensure that the brick panels, if used, are installed.

7)Verify log placement. If the pilot cannot be seen when lighting the unit, the logs have been incorrectly positioned.

8)The unit should never be turned off, and on again without a minimum of a 60 second wait.

LIGHTING

PROCEDURE

IMPORTANT

To ignite or reignite the pilot, you must first release the ten- sion springs below the door.

NOTE: For all propane units and units equipped with electric spark boxes, see "Copy of Lighting Plate Instruc- tions" section for more details.

Only when the pilot holds, without pressure being applied to the control knob, reapply the tension springs to the door. The unit must not be operated with the tension springs unattached.

 

not remain lit, repeat operation allowing a

 

longer period before releasing gas control

 

knob.

4)

When the pilot stays lit, turn the gas knob

 

further counterclockwise to the "ON"

 

position.

5)

Use the wall switch, thermostat or remote

 

control to turn on the unit.

6)

Rotate the flame height regulator to adjust

 

the flame height higher or lower.

SHUTDOWN

PROCEDURE

1)Use the wall switch, thermostat or remote control to turn off the main burner.

2)Turn the main gas control clockwise to the "OFF" position to turn off the pilot.

3)Turn off all electric power to appliance if service is to be performed.

20

U35 FPI Direct Vent Gas Insert

Page 20
Image 20
Regency U35-NG1, U35-LP1 Final Check, Operating Instructions, First Fire, Lighting Procedure, Shutdown Procedure