Remington 491 operating instructions Know Your Fastening Base Material

Models: 491

1 28
Download 28 pages 31.43 Kb
Page 6
Image 6

Safety Precautions

?

?

?

7.An operator taking medication should take extra precautions while handling the tool. Never drink alcoholic beverages or take medications which impair your vision, balance or judgement before using a powder actuated tool.

KNOW YOUR FASTENING BASE MATERIAL

? ?

?

?

482-26

Point flattens

TOO

482-29

CENTER

PUNCH TEST

482-27

Surface shatters

TOO BRITTLE

482-30

Sinks in with average hammer blow

482-28

Start

GREEN

POWER

LEVEL 3

YELLOW

POWER

LEVEL 4

RED

POWER

LEVEL 5

1.Always know the thickness and type of base material into which you are fastening. Never guess. Test the base material by using the Center Punch Test. The Center Punch Test is performed by using a hammer to test drive the particular power fastener to be used into the material. If the point penetrates easily, the material is too soft. If the point becomes blunt, the material is too hard. If the material fractures, cracks or shatters, the material is too brittle. Test fastenings can be made if the material shows a clear fastener impression and the fastener point is not blunted. Always start with the lowest power load (Green-Level 3) and proceeding with the order shown in the lower right-hand figure above. Always wear approved goggles.

6

099494

Page 6
Image 6
Remington 491 operating instructions Know Your Fastening Base Material