Troubleshooting Guide
PROBLEM | POSSIBLE CAUSE | REMEDY |
|
|
|
| |
Tool does not fire. | Dirt | Check firing pin mark on | |||||
| er not allowing proper | power | load. Clean | sear | |||
| penetration of firing pin | holder, | sear, | and | firing | ||
| or worn firing pin. | pin. Replace | worn or | ||||
|
| damaged parts. Notice: | |||||
|
| Do not attempt to clean | |||||
|
| power load strip channel | |||||
|
| with wire brush. You may | |||||
|
| damage the tool. |
|
| |||
|
|
| |||||
Opening and closing of | Lack of proper cleaning. | Inspect and clean com- |
| ||||
barrel or pushing down of |
| plete tool (see Mainte- | |||||
the tool, etc.is not smooth |
| nance on page 16). Re- | |||||
but is rough or binds. |
| place worn or damaged | |||||
|
| parts. Notice: Do not | |||||
|
| attempt to | clean power | ||||
|
| load strip | channel | with | |||
|
| wire brush.You may dam- | |||||
|
| age the tool. |
|
|
| ||
|
|
|
|
|
|
|
|
Application Chart
Power load and power fastener application information.
For fastening this | to this | power fastener | power load |
length | color |
Concrete
Two by foursCement block
Steel (3/16" to 3/8" thick)
2 1/2" | Yellow |
2 1/2" | Green |
2" | Yellow/Red |
Furring strips | Concrete | |
Cement block | ||
| ||
| Steel (3/16" to 3/8" thick) |
1 1/2" | Yellow |
1 1/2" | Green |
1 1/2" | Yellow/Red |
Electrical | Concrete | 1" | Yellow | |
Junction boxes | Cement block | 1" | Green | |
| Steel (3/16" to 3/8" thick) | 1" | Yellow/Red | |
Conduit clips | Concrete | 1" | Yellow | |
Cement block | 1" | Green | ||
| ||||
| Steel (3/16" to 3/8" thick) | 1" | Yellow/Red | |
Shelf brackets | Concrete | 1" | Yellow | |
Cement block | 1" | Green | ||
| ||||
1/4" Plywood or | Concrete | 1 1/4" | Yellow | |
Cement block | 1 1/4" | Green | ||
pegboard | ||||
Steel (3/16" to 3/8" thick) | 1 1/4" | Yellow/Red | ||
|
Power load listings are recommendations only. If you are in doubt, try a test fastening using the next lightest power load.
24 | 114915 |