Maintenance

IMPORTANT:

Clean your tool after each day’s use. The parts shown in the illustration below should be cleaned daily. Clean metal parts with accessory wire brushes. Apply penetrating lubricant sparingly and wipe dry.

 

Receiver

 

Barrel

 

Buffer

 

Tang

 

Tang Spring

 

Tang Cap

Muzzle Cap

Piston

 

Troubleshooting Guide

PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

Piston rod hangs out of muzzle

Piston not properly assembled

Remove barrel assembly.

cap.

in relation to tang.

Follow instructions for piston

 

 

change. Replace all damaged

 

 

or missing parts.

 

 

 

 

Broken piston.

Replace piston.

 

 

 

Overdriving of power fastener.

Excessive power.

Change either to next lower

 

 

power load, or use next longer

 

 

fastener length.

 

 

 

Piston jammed.

Overdriving of power fastener

Remove barrel assembly.

 

(see above).

Follow instructions for buffer

 

Buffer binding on piston in

replacement (page 21). Replace

 

muzzle cap.

other parts if damaged.

 

 

 

Expended power load will not

Dirty or damaged receiver

Clean receiver chamber. If

extract.

chamber.

power loads will not chamber

 

 

with a slip-fit or extraction

 

 

difficulties continue, take tool to

 

 

your distributor for repair.

 

 

 

Reduction or loss of power.

Piston not returning to full rear

Barrel must be opened fully to

 

position.

the full extended position to

 

 

properly position piston.

 

 

 

 

Worn piston ring.

Remove piston. Replace piston

 

 

ring.

 

 

 

 

Broken piston.

Replace piston.

 

 

 

 

 