Application Chart

 

Power load and power fastener application information.

 

 

 

power fastener

power load

For fastening this

to this

length

color

 

 

 

 

Two by fours

Concrete

Cement block

 

 

Steel (3/16" to 3/8" thick)

2 1/2"

Green

2 1/2"

Green

2"

Yellow

Furring strips

Concrete

1 1/2"

Green

Cement block

1 1/2"

Green

 

Steel (3/16" to 3/8" thick)

2"

Yellow

Metal electrical

Concrete

1"

Green

Cement block

1"

Brown

junction boxes

Steel (3/16" to 3/8" thick)

1"

Yellow

 

 

Concrete

1"

Green

Conduit clips

Cement block

1"

Brown

 

Steel (3/16" to 3/8" thick)

1"

Yellow

Shelf brackets

Concrete

1"

Green

Cement block

1"

Brown

 

1/4" Plywood or

Concrete

1 1/4"

Green

Cement block

1 1/4"

Green

pegboard

Steel (3/16" to 3/8" thick)

1 1/4"

Yellow

 

Power load listings are recommendations only. If you are in doubt, try a test fastening using the next lightest power load.

IMPORTANT

This tool is designed to use 22 caliber neck-down crimped loads, power levels 1 (gray) through 4 (yellow).

5/8"

 

 

 

G 018

 

Neck-Down

Straight Wadded

Crimped Power Load

Power Load

CAUTION

Do not use any load other than the 22 caliber neck-down crimped load. Other types of loads will cause load-ejection problems.