WATER

482-46

2.Should the tool fail to fire, hold the muzzle firmly against the work surface for 30 seconds. Release the trigger and remove pressure on the tool while holding the muzzle against the work surface. Again press the tool firmly against the work surface and pull the trigger. If the tool still fails to fire, hold the tool firmly against the work surface for another 30 seconds before unloading and carefully discarding the misfired power load into water or oil.

G018

3.ALWAYS use the spall shield when driving directly into concrete or steel. Always wear approved goggles

GASOLINE

OLINE

482-

G 018 482-49

G 018

4.NEVER use a powder actuated tool in an explosive or flammable atmosphere or when non- sparking tools are required.

POWER LOADS AND FASTENERS

G 018

POWER LOADS G 018

1.NEVER leave unfired power loads on floors or work surfaces.