108
11.1 Options Menu 11.1.1 Login...
This allows changing of which user is logged in to FDT. The hotkey Ctrl+Shift+U also invokes the Login
dialog.
11.1.2 Batch Erase Mode...
This will change the dialog to be erase based, rather than programming based. The ‘Program Flash’ button
will change to ‘Erase’, the file\image selection buttons will be disabled and the programming options will
also be disabled. Clicking ‘Erase’ will erase the whole device (it is not possible to specify the area to erase).
11.1.3 AutoDisconnect
This forces FDT to automatically disconnect after programming (or erase if in Batch Erase Mode), so that
the user does not need to press the Disconnect button.
11.1.4 Readback Verify
This option controls whether FDT automatically performs a read and compare operation after
programming. The setting is remembered between sessions.
11.1.5 Request Checksum
This option controls whether FDT automatically performs a ch ecksum request operation after
programming. The setting is remembered between sessions.
11.1.6 Erase Device Before Program
This option controls whether FDT automatically performs an erase operation before programming the
device. This will erase all blocks in all memory areas prior to programming. The setting is remembered
between sessions.
11.1.7 Security Protection
This option controls whether FDT should security protec t QzROM devices as it disconnects. Select
“Automatic” to always protect the device at disconnection. Select “Prompt” to query the user what to do
and select “None” to never protect the device at disconnect. NB – a protected device cannot be reconnected
to.
11.1.8 Field Programming->Run Published File…
Unpackage another .fpf file and use it in Simple Interface Mode.
11.1.9 About…
Shows the About box.