Step 1. Shut off main electrical power switch to heater.

Step 2. Turn heater manual switch located in upper control panel to the "OFF" position. Step 3. Shut off gas supply and water supply to the heater.

Step 4. Mount drafthood on top of boiler as shown on page 8. Drafthood should be positioned with the vent sensor located on the front right side as shown.

Step 5. Remove plastic plug from left side of boiler jacket and install plastic grommet provided. Step 6. Route flue sensor wire harness through the grommet installed in Step 5.

Step 7. Remove door and locate wire from roll out sensor to hi limit with the male/female connector.

Step 8. Disconnect male/female connector and attach to the 2 wires from draft hood vent sensor harness.

Fig# 9350

 

Fig# 9349

HEATER BEFORE

HEATER AFTER

DRAFTHOOD

DRAFTHOOD

INSTALLATION

INSTALLATION

 

 

MODELS 512 - 825

Locate and assemble as shown below. Secure with screws supplied in envelope in carton

Fig. #8167.0

13

Page 13
Image 13
Rheem 136-1826 installation instructions MODELS181-399, Heater Before Heater After Drafthood Installation

136-1826 specifications

The Rheem 136-1826 is a highly efficient heating and cooling unit designed to provide reliable performance and comfort in residential settings. This unit is particularly notable for its advanced features, robust technologies, and outstanding characteristics that set it apart in the HVAC market.

One of the defining features of the Rheem 136-1826 is its energy efficiency. Rated with a high Seasonal Energy Efficiency Ratio (SEER), this unit efficiently converts energy into cooling output, leading to significant savings on utility bills. The environmentally friendly refrigerants used in its operation comply with current global regulations and aim to minimize any negative impact on the ozone layer.

Additionally, the Rheem 136-1826 incorporates advanced climate control technologies. Its innovative multi-stage compression offers superior cooling performance and an enhanced ability to maintain comfortable temperatures, even during extreme weather conditions. The variable-speed motor allows for precise airflow management, leading to quieter operation and improved indoor air quality by minimizing dust and allergens in circulation.

Another remarkable attribute of the Rheem 136-1826 is its smart technology integration. Homeowners can connect the unit to Wi-Fi and control it remotely through a mobile app. This feature not only provides convenience but also allows users to monitor system performance, adjust settings, and receive maintenance reminders. The programmable thermostat included in the setup further enhances energy conservation efforts, enabling users to tailor their heating and cooling schedules to their lifestyle.

In terms of installation and maintenance, the Rheem 136-1826 has been designed with user-friendliness in mind. Its compact size allows for easy installation in various locations, making it a versatile choice for different home designs. The durable construction materials used in this unit ensure longevity and reduced maintenance needs over time.

Overall, the Rheem 136-1826 stands out for its combination of energy efficiency, advanced cooling technologies, smart features, and ease of use. It is an ideal choice for homeowners looking for a reliable and efficient heating and cooling solution that not only enhances indoor comfort but also contributes to long-term energy savings. Whether replacing an old system or installing a new one, the Rheem 136-1826 is well-equipped to meet the demands of modern living.