Notice: The remote control cannot be turned on when water is flowing or circulating through the water heater..

Notice: Display shows °F only..

Water Temperature Setting…

Maximum water temperature occurs while

 

control(s) should be used..

the burner is on.. To determine the water

 

 

 

The hottest temperature water will be at the

temperature, turn on a hot water faucet and

 

 

hot water faucet closest to the water heater..

place a thermometer in the water stream..

 

 

 

 

 

 

 

 

 

 

 

Water temperature at the faucet may vary

 

Always remember to test the water

depending on season and length of pipe

 

 

 

temperature with your hand before use and

from the water heater..

 

 

 

remember that hotter water increases the risk

The factory setting of the remote control

 

 

 

of scald injury..

 

 

 

 

 

 

 

 

 

 

temperature range is between 100°F (38°C)

 

Always supervise young children or others

and 120°F (49°C)..

 

 

 

who are incapacitated..

The remote control is factory preset to 100°F

The water heater is equipped with a device

(38°C).. To turn the remote control ON or

 

that will shut off the gas supply to the burner

OFF, press the POWER button..

 

 

 

if the water heater exceeds normal operating

To adjust the temperature to a required setting,

temperatures.. Refer to the “Before You Call

For Service” section located near the back of

press the UP arrow temperature button..

 

 

 

 

 

 

this manual, or contact your dealer..

Pressing the UP or DOWN temperature

 

 

 

 

 

 

! WARNING: Should overheating

adjustment buttons will change the

 

 

 

 

 

 

occur or the gas supply fail to shut off,

temperature set point..

 

 

 

 

 

 

turn off the manual gas control valve

 

 

 

 

 

 

 

The temperature set point on the remote

 

 

 

to the appliance.

 

 

control cannot be increased above 112°F

 

 

 

If the water heater has been subjected to

(44°C) when a hot water faucet is in the

 

 

 

 

 

 

fire, flood, physical damage, or has been

open position..

 

 

 

 

 

 

under water, turn off the manual gas shut-off

 

 

 

 

 

 

 

Notice: The factory setting allows operating

 

valve(s), and do not operate the water heater

temperatures between 100°F (38°C) and

 

 

 

again until it has been checked by qualified

120°F (49°C).. Temperatures of 85°F (29°C)

 

personnel..

 

 

and above 120°F (49°C) can be achieved

 

Notice: The water heater may not operate

with the MAIN (UMC-117) remote control..

 

with a small water flow.. In such case, increase

Temperatures of 85°F (29°C) can be

 

 

 

the water flow.. If water heater still does not

achieved with the Bath (USC-117 or

 

 

 

operate and hot water faucet is completely

USC2-117) remote control.. Only qualified

open, increase the temperature setting on the

service personnel should perform this

 

 

 

remote control..

 

 

adjustment.. Only factory authorized remote

 

 

 

 

 

 

In Use Indicator

 

 

 

 

 

 

Priority Indicator

 

 

 

 

 

 

 

 

(Lit during operation)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED Display

 

 

 

PRIORITY

 

 

 

Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Displays water

 

 

 

 

 

°F

 

 

 

 

Adjustment

 

 

 

 

 

 

 

 

 

temperature and error

 

 

 

 

 

 

 

 

 

Buttons

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

codes)

 

 

 

 

 

 

 

 

 

 

ON/OFF

 

 

 

 

 

 

POWER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON/OFF

 

Indicator

 

 

 

 

 

 

 

 

 

 

 

Higher (Hotter)

 

 

 

Lower (Cooler)

 

85

100 102 104 106 108 110 112 114 116 118 120*

125 130 135 140

°F

29

38

39

40

41

42

43

44

46

47

48

49*

52

54

57

60

°C

* Temperatures 85°F (29°C) and above 120°F (49°C) can be achieved with the

 

MAIN (UMC-117) remote control.. See page 34 and 35 for maximum and

27

minimum temperature adjustment..

Page 27
Image 27
Rheem RUTG-66DV, P), PH-25RDVS, RMTG-66DV, ECO-180DV warranty Water Temperature Setting…