Rheem ECO-180DV, P) Venting System Inspection, Burner Inspection, Vacation and Extended Shut-Down

Models: RMTG-66DV RUTG-66DV ECO-180DV PH-25RDVS P)

1 36
Download 36 pages 8.56 Kb
Page 29
Image 29

Housekeeping, continued

!DANGER: DO NOT attempt to operate the water heater without the air intake filter.

CLEANING THE WATER HEATER AND REMOTE CONTROL(S):

Make sure the unit is OFF and the electrical power supply has been disconnected..

DO NOT scrub the appliance with a brush..

Use only mild soapy water; other cleaners may damage the surface of the water heater..

DO NOT remove any label including the rating plate while cleaning or servicing..

DO NOT splash water on the remote controls when cleaning..

Venting System Inspection

The venting system of a direct vent water heater should be inspected annually to ensure all of the vent sections are secure and air- tight..

It is recommended that qualified service personnel familiar with Category III venting inspect the venting system..

Check vent connection joint sections with a solution of soapy water to assure air-tightness while the unit is operating..

Bubbles around a joint connection indicates a seal leak.. Refer to page 9 for vent sealing instructions..

DO NOT operate the unit if vent system shows signs of leaking exhaust..

Check to make sure that the air intake and vent outlet on the termination has not been blocked or contain debris..

Burner Sight

Burner Inspection

Glass

 

Visually inspect the main burners annually..

 

Through the front sight glass, inspect the

 

burner flame.. Blue flames should be seen

 

when the main burner is firing.. See the figure

 

on the left for location of sight glass..

 

If any unusual burner operation is noted, the

 

water heater should be shut off until qualified

 

service assistance can be obtained..

!CAUTION: For your safety, burner inspection and cleaning should be performed only by qualified service personnel.

For cleaning, a vacuum cleaner can be used on the burner..

NOTICE: Refer to the Freeze Protection Section on page 30.

Vacation and Extended Shut-Down

If the water heater is to remain idle for an

After a long shut-down period, the water

extended period of time, the power and water

heater’s operation and controls should be

to the appliance should be turned off..

checked by qualified service personnel..

The water heater and piping should be

 

drained if they might be subjected to freezing

 

temperatures..

 

!CAUTION: Do not operate without the condensate trap connected to the vent and routed to the proper drain.

Condensate Trap Inspection

On a regular basis, inspect the condensate trap to ensure there is enough water in the trap and the condensate is draining properly..

Ensure that condensate is disposed of per local codes and regulations..