Rheem ECO-180DV, P), PH-25RDVS, RUTG-66DV, RMTG-66DV warranty 135F 57C

Models: RMTG-66DV RUTG-66DV ECO-180DV PH-25RDVS P)

1 36
Download 36 pages 8.56 Kb
Page 34
Image 34

The content on this page is intended for use by qualified

installation/service personnel ONLY.

WARNING: Improper adjustment, alteration, service or maintenance can cause property damage, personal injury, or death.

Maximum Temperature Adjustment by the Main Remote Control (UMC-117)

Required adjustment for up to 140°F (60°C) water temperature settings

!WARNING: Refer to scald potential warnings on page 4 before making adjustment.. Changing this setting is done at your own risk..

DO NOT execute the following adjustment if the setting of up to 140°F (60°C) is not required.

!DANGER: Hotter water increases the potential for Hot Water SCALDS.

Time/Temperature Relationship in Scalds

Water Temperature

 

 

Time To Produce a Serious Burn

 

 

 

 

 

120°F (49°C)

 

 

More than 5 minutes

125°F (52°C)

 

1-1/2 to 2 minutes

130°F (54°C)

 

About 30 seconds

135°F (57°C)

 

About 10 seconds

140°F (60°C)

 

Less than 5 seconds

145°F (63°C)

 

Less than 3 seconds

150°F (66°C)

 

About 1-1/2 seconds

155°F (68°C)

 

About 1 second

Table courtesy of Shriners Burn Institute

 

 

 

 

 

Follow the instructions below if it is determined that a setting of up to 140°F (60°C) is required.

Turn on the remote control. Turn off the gas and water shutoff valves.

Press the UP arrow temperature adjustment button on the remote control for several times and set the temperature at 120°F (49°C).

Press and hold the UP button on remote control for more than 5 seconds. Number (120) on the display of the remote control will begin to blink.

While the number is blinking, push the UP arrow temperature adjustment button and the Down arrow temperature adjustment button at the same time. The display of the remote control will show “140”.

Push the UP or Down button to set desired temperature.

Turn on the gas and water shut off valves.

Check and ensure safe operation and performance of the water heater.

See steps below to LIMIT maximum water temperature setting to 120°F (49°C).

Turn on the remote control. Turn off the gas and water shutoff valves.

Press the Down arrow temperature adjustment button on the remote control for several times and set the minimum setting temperature (100°F(38°F) or 85°F(29°F)).

Press and hold the Down button on the remote control for more than 5 seconds. Number on the display of the remote control will begin to blink.

While the number is blinking, push the Down arrow temperature adjustment button and the UP arrow temperature adjustment button at the same time. Number of the display of the remote control will stop blinking.

Push the UP or Down button to set desired temperature.

Turn on the gas and water shut off valves.

Check and ensure safe operation and performance of the water heater.

 

In Use Indicator

Notice: Display shows

(Lit during operation)

 

°F only..

LED Display

 

(Displays water

 

temperature and error

 

codes)

 

Priority Indicator

PRIORITY

Temperature

 

°F

Adjustment

Buttons

 

POWER

ON/OFF

ON/OFF

Indicator

 

 

 

Higher (Hotter)

 

 

 

Lower (Cooler)

 

34

85

100 102 104 106 108 110 112 114 116 118 120*

125 130 135 140

°F

29

38

39

40

41

42

43

44

46

47

48

49*

52

54

57

60

°C

 