Installing the water heater.

Roof Survey

NOTICE: A roof in poor condition may need replacement before the system is installed.

Record the following on the checklist:

The type of roofing material (tile, shingle, tar & gravel, metal, etc.).

The condition of the roof. Note any repair requirements

needed prior to installation.

Draw diagram (top view) as shown below, of installation area. Mark location of the system and stub-out.

Using the table below, select the appropriate supporting structure for your solar system.

Roof Type

Installation Type

Supporting Structures

 

 

 

All types except sturdy tiles and

With pitch (standard)

4 runners and Collector Extrusion

metal

 

 

 

 

 

Sturdy tiles or metal roof with

With pitch (metal / sturdy tile)

Collector Extrusion only

No obstruction of water flow

 

 

 

 

 

All types

Side pitch

2 runners + Frame

 

 

 

All types

Reverse pitch

2 runners + Frame

 

 

 

All types

Flat / shallow pitch

2 runners + Frame

 

 

 

Roof Support Requirements

The system weighs up to 1089 lbs (80 Gallon System) when installed and filled. It may not be necessary to provide additional support but you must inspect the roof support system to determine if additional bracing is needed.

Record the following on the checklist.

!CAUTION: If the following modifications do not apply to the installation site, an engineer must specify support modifications.

Conventional Roof Modifications;

Locate the load bearing wall beneath installation site (refer to building plan if available) and indicate on the roof-site plan. If a load-bearing wall is not available, note this on the checklist.

Review Figure at the top of the following page and select correct supports.