Rheem RS80-42BP, RS47-21BP Customer Approval, Branch Circuit Sizing and Wire Size Guide

Models: RS47-21BP RS80-42BP

1 40
Download 40 pages 48.13 Kb
Page 14
Image 14

Installing the water heater.

Review the checklist for installation requirements.

Check the following before beginning installation. Permits

Obtain required permits before installation.

Work Force

An 80 gallon storage tank weighs up to 242 lbs empty, requiring a crew of two or more to install.

Inventory

Review Section on Frames, included hardware, and all optional supplies before beginning installation.

Required Tools, Equipment and Supplies

Basic Plumbing, Electrical and Carpentry Supplies

Metric wrench (36 mm open end wrench)

12” pipe wrench

Two 12” adjustable (crescent)

Wrenches

Water pressure gauge

Crowbar

Copper tubing cutter

Soldering kit

Caulking gun

24” Spirit (bubble) level

Cable cutter / stripper

6” diagonal cutting and long nose pliers

100' Grounded extension cord

Screwdriver Set (# 2 Philip’s, 1/4” Slotted)

Tape measure (100 Foot)

16-Ounce claw hammer

Marking pen

Utility knife

3/8”-drive socket set

2 Extension ladders

Flashlight / electric lantern

Pipe vice / cutter / threader

Volt, ohm, ammeter

Hacksaw

1/2” Electric drill with bit set

Skill Saw with standard and masonry blades

Crane, if required

1” Wood-boring bit

Consumable Supplies:

Masking/duct tape

Wood/sheet metal screws

Dielectric pipe unions

Waterproof sealing compound

5/16” Lag Screws, 1 3/4”, 2”, 3”, 6”, as required

Washers

Nails, 16g, or assorted, as required

Silicone sealant

2' x 4' x 8'4” redwood, treated-wood or

Unistrut runners, as required

Customer Approval

Review the checklist with the customer and discuss all installation requirements and procedures.

• Ask the customer to sign the checklist.

NOTICE: This guide recommends minimum branch circuit sizing and wire size based on National Electric Code. Refer to the wiring diagrams in this manual for field wiring connections.

Branch Circuit Sizing and Wire Size Guide

Total Water

Recommended Over Current Protection

Copper Wire Size AWG Based

 

Heater Wattage

(fuse or circuit breaker amperage rating)

on N.E.C. Table 310-16 (75°C)

 

 

208V

 

240V

 

277V

 

480V

208V

 

240V

 

277V

 

480V

 

 

 

 

 

 

 

3,000 or lower

20

 

20

 

15

 

15

12

 

12

 

14

 

14

4,000

25

 

25

 

20

 

15

10

 

10

 

12

 

14

4,500

30

 

25

 

25

 

15

10

 

10

 

10

 

14

14

Page 14