System Settings (Parallel Connection)

System Settings (Parallel Connection)

Parallel Timing

Specifies the timing for the parallel interface. Normally, you do not need to change this setting.

ACK Inside

ACK Outside

STB Down

Note

Default: ACK Outside

Parallel Communication Speed
Bidirectional Communication

Specifies, for instance, how a print- er connected to the parallel inter- face responds to a status request. If you experience problems using an- other manufacturer’s printer, set this to Off.

Limitation

If set to Off, asynchronous com- munication will not work.

• On

Specifies the communication speed of the parallel interface. If the speed is too high, data may not be transferred smoothly. If this happens, change the setting to “Standard”.

High Speed

Standard

Note

Default: High Speed

Selection Signal Status

Specifies the signal level of the par- allel interface.

• High

• Low

Note

Default: High

Input Prime

• Off

Note

Default: Off

Signal Control

Specifies how to handle any errors that occur when printing from a computer. Normally, you do not need to change this setting.

• Job Acceptance Priority

Printer Priority

 

8

Facsimile Priority

 

Note

Default: Job Acceptance Priority

Specifies whether the prime signal is active or inactive when an input prime signal is sent. Normally, you do not need to change this setting.

Effective

Invalid

Note

Default: Invalid

159