RIDGID Comprehensive Troubleshooting Guide for Hydraulic Pipe Cutters

Models: 258 258XL

1 43
Download 43 pages 30.9 Kb
Page 14
Image 14

258/258XL Power Pipe Cutters

Troubleshooting

Troubleshooting Table

 

Problem

 

Cause

 

 

Correction

 

 

 

 

 

 

 

 

 

Foot pump does not

 

Hose connections are not complete

 

 

Insure hoses from pump to ram are completely

 

advance ram

 

 

 

 

secured

 

 

 

 

Low hydraulic fluid

 

 

Insure fluid level is at full capacity

 

 

 

 

Air in hydraulic system

 

 

Bleed system

 

Cutter wheel does not

 

Cutter is not firmly clamped to pipe

 

 

Insure cutter squares itself to the pipe by pump-

 

track

 

 

 

 

ing several times before starting power drive

 

 

 

 

Pipe is not properly supported

 

 

Short lengths of pipe must rest squarely on cutter

 

 

 

 

 

 

 

frame rollers. Long lengths must be supported

 

 

 

 

 

 

 

with stands so the cutter can locate itself to pipe

 

 

 

 

 

 

 

Pump 2 to 3 strokes on foot pump after cutter

 

 

 

 

Cutter wheel has not been preloaded 2 or 3

 

 

wheel contacts the pipe before starting the 700

 

 

 

 

pumps before starting 700 power drive

 

 

Power Drive

 

Pipe does not rotate

 

Cutter wheel is not properly assembled

 

 

Insure cutter wheel is free to rotate in either direc-

 

 

 

 

 

 

 

tion in hub assembly (See Directions)

 

 

 

 

774 Square Drive Adapter is not completely

 

 

Square Drive Adapter must be fully inserted,

 

 

 

 

inserted in 700 gear head

 

 

spline first into gear head

 

 

 

 

 

 

 

Insure that pipe is free of flat areas or has not

 

 

 

 

Pipe is out-of round

 

 

been crushed

 

700 motor does not start

 

Interruption of power supply

 

 

Examine supply

 

 

 

 

Fuse blown

 

 

Install fuse

 

 

 

 

Brushes do not touch armature

 

 

Check the brushes, renew used brushes

 

Abnormal heating of

 

Overload because of continuous operation

 

 

Let power drive cool after continuous use

 

motor

 

Insufficient cooling air

 

 

Clean the air-vent opening of the motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

Ridge Tool Company

Page 14
Image 14
RIDGID 258XL manual Troubleshooting Table Problem Cause Correction