SeekTech
Figure 45: Editing a User-Defined Frequency
(Note: Trash Icon for deleting Frequency appears when
Frequency is set to 0).
3.Use the arrow keys to move through the digits and increase or decrease them.
4.When the frequency is correct, press the Select Key to save the new value.
To delete a
1.Press the Menu Key to show the list of active frequencies. Scroll down to the
2.Press the Frequency Key . The
3.For each digit that is not set to zero, select the digit and use the Down arrow key to reduce it to zero.
4.When all digits in the frequency are set to zero, the “trash can” icon will appear. Press the Select Key . The
Figure 46: User-Defined Frequency Screen
Menus and Settings
Pressing the Menu Key brings up a series of choices which let the operator configure the
Auto Menu Exit Count-down Timer
While traversing the menu tree, a counter appears at the bottom of the screen counting down. When it reaches zero, it will automatically move back up one level of the menu tree until it reaches the operating screen again. It resets to nine with each key press, or each time it goes up one menu level, until it reaches the operating screen.
Figure 47: Main Menu
In sequence from the top of the menu down, the Main Menu presents the following items:
1. SimulTrace (512 Hz + 33 kHz) (If activated).
2. Currently Available Sonde frequencies
3. Currently Available Active Line Trace frequencies
4. Currently Available Power (Passive Line Trace) frequencies
5. Currently Available Radio Frequencies (Low and High)
6. OmniSeek Mode
7. Depth Measurement Units Setting
8. Backlight Control.
9.
10. LCD Contrast Control
Ridge Tool Company Elyria, Ohio U.S.A | www.seektech.com | 29 |