SeekTech SR-60

Set up

Once the SR-60 is up and running, the next step is to set up the frequencies needed to match the transmitter frequency being used, or the frequency of the line to be located. Each frequency is selected for use by choosing it from a list in the Main Menu. If the box on the Main Menu for that frequency is checked, the frequency is “Checked-Active”.

Checked-Active frequencies are already selected for use and appear in sequence when pressing the Frequency Key . (For example, the line trace frequency of 33 kHz is available by pressing the Frequency Key and advancing through the list until 33 kHz is reached.)

NOTE: When a frequency is highlighted in the Main Menu, pressing the Frequency Key will display its exact frequency value. For example, 8 kHz = 8192 Hz.

A long press on the Frequency Key will bring up a scrollable list of all Checked Active frequencies.

Figure 11: Frequency Key

Figure 12: Line Trace Frequency Selected with

Frequency Key

Activating Frequencies

Frequencies can be chosen for the set of Checked- Active frequencies so they will become available using the Frequency Key . Frequencies can also be deactivated to keep the frequency set smaller.

Each frequency is activated by choosing it from a list in the Main Menu (See Figure 14). Frequencies are grouped by category:

SimulTrace (512 Hz + 33 kHz) (if active)

Sonde

Active Line Trace

Power (Passive Line Trace) Radio

OmniSeek (multi-RF bands)

1. Push the Menu Key :

Figure 13: Menu Key

The Main Menu screen is then activated:

Figure 14: Main Menu

2.Using the Up and Down Keys, highlight the frequency desired (Figure 15). In this example, the operator is activating the 8 kHz frequency.

Ridge Tool Company  Elyria, Ohio  U.S.A

www.seektech.com

11

Page 13
Image 13
RIDGID SR-60 manual Set up, Activating Frequencies