SeekTech SR-60

11. Display Elements Control (Sub- menus will display when selected for Sonde or line tracing modes.)

12. Frequency Selection Control (Sub-menus will display for categories of frequencies that can be selected.)

13. Information Menu including software version and unit serial number (sub-menu for restoring factory defaults will display on Information screen).

See the Menu Tree on page 35 for a complete list.

SimulTrace Mode

The SimulTrace mode is off by default and can be activated by selecting it in the Frequency Selection Control sub-menu. It provides simultaneous tracing of a 512 Hz Sonde and a 33 kHz line for easier tracking of underground pipes using a Sonde.

Currently Available Sonde Frequencies

Frequencies that have been set to “Checked-Active” status appear with a check box next to them. If the checkbox is checked, the frequency can be accessed using the Frequency Key . Frequencies are checked or unchecked by highlighting them and pressing the Select Key. To return to the operating screen, press the Menu Key.

See the Frequency List on page 9.

Currently Available Active Line Trace Frequencies

Frequencies that have been set to “Checked-Active” status appear with a check box next to them. If the checkbox is checked, the frequency will be activated and can then be accessed using the Frequency Key . Frequencies are checked or unchecked by highlighting them and pressing the Select Key. To return to the operating screen, press the Menu Key.

See the Frequency List on page 9.

Currently Available Passive Line Trace

Frequencies

As with other frequency categories, these items will appear in the “Checked-Active” set when checked.

See the Frequency List on page 9.

Currently Available Radio Frequencies

As with other frequency categories, these items will appear in the “Checked-Active” set when checked.

See the Frequency List on page 9.

OmniSeek Mode

The OmniSeek mode allows simultaneous tracing in multiple high-frequency bands: <4 kHz, 4-15 kHz, and 15-35 kHz.

Change of Depth Units

The SR-60 can display Measured Depth in either Feet or Meters (Figure 48). Feet are shown in feet-and-inches format; meters are in decimal format. To change these settings, highlight the Depth Units selection in the menu and press the Select Key to toggle between feet or meters. Use the Menu Key to save the section and exit.

Figure 48: Selecting Units (Feet/Meters)

Back Light Control

A light detector built into the upper left corner of the keypad senses low light levels. The backlight can be forced on by blocking the light to this sensor.

The automatic LCD backlight is factory set to only switch on under fairly dark conditions. This is to conserve battery power. As the batteries near depletion, the backlight will appear dim.

To set the backlight to be always off, highlight the light bulb icon in the tools section of the menu. Press the Select Key to toggle it between Auto, always ON and always OFF.

30

www.seektech.com

Ridge Tool Company  Elyria, Ohio  U.S.A

Page 32
Image 32