Rinnai user manual Technical Details, Infinity 24e

Models: 24e

1 39
Download 39 pages 46.41 Kb
Page 10
Image 10
TECHNICAL DETAILS

TECHNICAL DETAILS

Infinity Model

Infinity 24e

Units

 

 

 

Installation

External

 

 

 

 

Nat Gas Press Low

0.8

mbar

 

 

 

Nat Gas Press High

9.0

mbar

 

 

 

LPG Press Low

1.7

mbar

 

 

 

LPG Press High

22.6

mbar

 

 

 

Height

600

mm

 

 

 

Width

350

mm

 

 

 

Depth

170

mm

 

 

 

Weight

18

kg

 

 

 

Flue System

Forced Exhaust

 

 

 

Temp. Range Controllers

37 - 75

deg C

 

 

 

Temp. Range without

37,40,43,50,

deg C

Controllers

55*,65,75

 

Ignition

Direct Electronic

Ignition

 

 

 

Gas Consumption Low

 

 

 

 

 

Nat Gas

5.8

kW

 

 

 

LPG

5.8

kW

 

 

 

Gas consumption High

 

 

 

 

 

Nat Gas

52

kW

 

 

 

LPG

52

kW

 

 

 

Max Flow raised 33C

18

L/min

 

 

 

Min Operation Flow

2.7**

L/min

 

 

 

Water Pressure Nom.

1.4 - 10

bar

 

 

 

Power Supply

230 V / 50 Hz

 

 

 

Elec. Consumption Standby

6

Watts

(with 1 remote connected)

 

 

Elec. Consumption Run

55

Watts

 

 

 

Elec. Consumption

100

Watts

Anti-frost Heaters On

 

 

* Factory Setting

**Minimum operation flow based on temperature setpoint and inlet conditions.

10

Page 10
Image 10
Rinnai user manual Technical Details, Infinity 24e