Clearances
recommended
Description | Clearance Required | Additional Detail |
|
|
|
(A) Below eaves, | 39.37 in (1000 mm) | If the projection is a shade cloth or material awning then |
balconies, or other |
| this is deemed as a combustible material and the |
projections |
| recommended clearance is 59.05 in (1500 mm). |
(B) From the ground or | 3.94 in (100 mm) cabinet | Ground level to bottom of fireplace. In cabinet |
other surface |
| installations, for optimal viewing while standing or sitting it |
|
| is recommended to position the burner assembly |
| Recommended 27.6 in (700 | inches |
| mm) freestanding | cabinet option at a lower level, allow enough room for the |
|
| gas connection underneath. |
|
|
|
(C) Walls | 19.68 in (500 mm) | Side of appliance to side wall. |
|
|
|
Gas and Electricity | 39.37 in (1000 mm) |
|
Meters |
|
|
|
|
|
Drain Pipe | 5.91 in (150 mm) |
|
|
|
|
Openable Windows | 19.68 in (500 mm) | From an openable window, door, or |
and Doors |
| inlet, or any other opening into a building, with the |
|
| exception of |
Mechanical Air Inlet | 78.74 in (2000 mm) | For example, an air conditioning unit |
|
|
|
Mantles or protrusions
39.37in (1 m) safe distance for fixed objects
Installation specific clearances
Ensure clearance for servicing
CANNOT be installed above the unit if any part of the surround is made of combustible material. If installing into a
Fixed objects such as outdoor furniture, umbrellas and plants should be at least 39.37 inches (1 m) away from the unit while it is in operation.
Additional clearances also need to be observed for the specific installation applications, detailed on the following pages.
Ensure enough room is maintained around the appliance for servicing, cleaning, and general access.
This appliance must be installed as a permanent fixture in an outdoor area.
Rinnai Corporation ROF4500 | 13 |