Installing Body Assembly in an Open 1-Sided or 2-Sided Installation

Angled Clearance

Designed to ensure combustible framing is greater than 1 inch (25 mm) from the sides of

Brackets

the unit as shown.

Top View

Open 1-sided

Cabinet

48.3 in (1225 mm) minimum

timber stud

non combustible

19.7 in

cabinet

(500 mm)

cladding

 

 

minimum

 

clearance

 

bracket

Top View

timber stud

Open 2-sided

 

Cabinet

 

clearance bracket

46.5in (1180 mm) minimum

47.0in (1195 mm) maximum

48.3in (1225 mm) minimum

cabinet

46.5in (1180 mm) minimum

47.0in (1195 mm) maximum

non combustible cladding

18.5 in

(470 mm) minimum

To install:

1.Measure the distance between studs to ensure clearances are adequate, horizon- tally and vertically.

2.Screw clearance brackets to the inner side of stud.

3.Ensure that the flat face of the clearance bracket is facing out as shown above.

Clad Surround

Refer to the section, Guidelines for Cladding and Finishes.

16

Rinnai Corporation ROF4500

Page 16
Image 16
Rinnai 4500 installation manual Timber stud