Guidelines for Cladding and Finishes

These are guidelines only. It is up to the installer to seek advice from the cladding supplier as to the correct application and specification of the material.

All materials and finishes directly above the appliance must be capable of withstanding the following temperatures:

with the door assembly installed 302° F (150° C)

without the door assembly installed 212° F (100° C)

Cladding materials shall be non-combustible and suitable for an outdoor environment.

If you are installing a door assembly, a heat rated material such as calcium silicate board must be above the fire. Such materials require installation and sealing in accordance with the supplier specification.

Rinnai accepts no responsibility for deterioration of cladding or finishes.

heat rated material capable of withstanding 302° F (150° C) is required above the appliance with the door assembly installed