Operating Instructions
Before Starting the Appliance
•Remove the weather cover.
•Inspect the burner before each use of the appliance. Ensure that no debris such as leaves or other objects have entered or are on the appliance. If the burner is damaged, it must be replaced with a Rinnai authorized replacement burner prior to operating the appliance.
•Completely open the door (if present).
•Inspect the gas supply hose before each use of the appliance. If there is evidence of abrasion or wear, or if the hose is damaged, it must be replaced with a Rinnai authorized replacement hose prior to operating the appliance.
Operating the Appliance
1.Turn on the gas supply.
2.Press the control knob and slowly turn counterclockwise until you hear a click. This step is “lighting to pilot”. Look for the pilot flame.
3.Hold down for an additional 5 seconds to activate the flame and then release.
NOTE: Steps 1 and 2 may need to be repeated several times to ignite the fire. This will vary according to the gas being used.
4.Once the heater is on, turn the knob to the high setting for a period of time in order to establish a flame pattern. You can modulate the flame by adjusting between the high and low settings.
5.To turn off, press the control knob and turn clockwise to the OFF position. When shutting down the appliance it is important to cover the appliance with the weather cover after it has cooled down.
6.Turn off the gas supply when the appliance is not in use.
TOP VIEW
Check for pilot flame after turning the knob to the pilot position
8 | Rinnai Corporation ROF4500 |