UHD LOW PROFILE DUCT FURNACE INSTALLATION OPERATION AND SERVICE MANUAL
13.7 Maintenance Checklist
Installation Code and Annual Inspections:
All installation and service of ROBERTS GORDON® equipment must be performed by a contractor qualified in the installation and service of equipment sold and supplied by
To help facilitate optimum performance and safety,
Annual Fall | Follow entire |
| operation. |
|
|
The Vicinity of the Heater | Do not store or use flammable objects, liquids or vapors near the heater. |
| Immediately remove these items if they are present. |
| See Page 5, Section 3. |
|
|
Vehicles and Other | Maintain the clearances to combustibles. |
Objects | Do not hang anything from, or place anything on, the heater. |
| |
| Make sure nothing is lodged in between the heat exchanger tubes. |
| Immediately remove objects in violation of the clearances to combustibles. |
| See Page 6, Section 4. |
|
|
Vent Pipe/Terminals | Venting must be intact. Using a flashlight, look for obstructions, cracks on the |
| pipe, gaps in the sealed areas or corrosion. |
| The area must be free of dirt and dust. |
| Remove any carbon deposits or scale using a wire brush. |
| If the vent terminal has a screen built in, remove any dirt, dust or deposits |
| from the screen. |
| See Page 19, Section 8. |
|
|
Cabinet Exterior | After installation, touch up scratches. Periodic painting should be done there- |
| after as required. Warning labels and logo labels should be legible and accu- |
| rate. Please contact |
| independant distributor if you need replacement warning labels or logo labels. |
| See Page 2, Figure 1 through Page 3, Figure 2 |
|
|
32 of 47