Roberts Gorden Ignition Control, CTCUA Axial Fan/Guard/Motor Assembly, See Page 6, Section

Models: CTCU 7 CTCU 22 CTCU 11 CTCU 15 CTCU CTCU 27

1 40
Download 40 pages 58.38 Kb
Page 37
Image 37
15.6 Ignition Control

SECTION 15: REMOVAL AND REPLACEMENT PARTS

15.6 Ignition Control

The control plugs onto the gas valve. Pull out 12 pin electrical connection. Pull out ignition cable and flame probe cable noting their positions

Release screw securing control to gas valve. Refit in reverse. Ensure correct location of ignition and flame probe cables. Ensure that the earth connection is made directly to the earth point on the gas valve.

15.7 CTCUA Axial Fan/Guard/Motor Assembly

The axial fan unit for the CTCUA heater is supplied completely assembled and balanced.

15.7.1 Fan Removal and Replacement

Remove the screws

and washers.

15.8Fan and Limit Thermostats 15.8.1 Removal and Replacement

1. Pull off the electrical connections to the thermostat

2.Unscrew the two screws securing the thermostat

3.Fit a new thermostat with two screws ensuring that the correct temperature setting and type are selected.

See Page 6, Section 4.3.

4.Reconnect the electrical connections and test operation.

Description

Part Number

Axial Fan CTCU-7

11111910

Axial Fan CTCU-11

11111911

Axial Fan CTCU-15

11111920

Axial Fan CTCU-22

11111921

Axial Fan CTCU-27/32

11111922

15.7.2 To Replace the Fan Assembly

To replace the fan assembly, reverse the procedure shown above. Fit rubber washers to the guard mountings to reduce vibration.

Check that the fan blades are free to rotate before turning on the power to the fan.

Strictly comply with the colour code of the fan wires to ensure correct operation. See Page 14, Section 9.3 wiring diagram.

Use only genuine ROBERTS GORDON® replacement parts.

31

Page 37
Image 37
Roberts Gorden Ignition Control, CTCUA Axial Fan/Guard/Motor Assembly, Fan Removal and Replacement, See Page 6, Section