Roberts Gorden CTCU 22, CTCU 27, CTCU 15 Fire Hazard, close to heater, injury or property damage

Models: CTCU 7 CTCU 22 CTCU 11 CTCU 15 CTCU CTCU 27

1 40
Download 40 pages 58.38 Kb
Page 40
Image 40
close to heater.

Attach this information to the wall near the ROBERTS GORDON® heater

®

Read the installation, Commissioning, Operation and Service Manual thoroughly before installation, operation or service.

OPERATING INSTRUCTIONS

WARNING

 

 

 

 

 

1.STOP! Read all safety instructions on this information sheet.

2.Open the manual gas valve in the heater supply line.

3.Turn on electric power to the heater.

4.Set the thermostat to desired setting (above ambient temperature). The automatic starting sequence begins.

NOTE: Following long shutdown periods, the burner control may go to to 'LOCKOUT' during the start sequence. Push the reset button to recommence firing. Contact service department if 'LOCKOUT' continues (see manual for details).

TO TURN OFF THE HEATER

 

 

 

 

 

 

 

 

Fire Hazard

1. Turn the thermostat/time switch to 'OFF'. The burner will turn 'OFF'

 

 

 

immediately, but fans will continue to cool heat exchanger until the fan

Some objects can catch fire or explode when placed

thermostat switches off.

 

 

 

 

 

 

 

 

 

close to heater.

IF THE HEATER WILL NOT OPERATE, TO ENSURE YOUR SAFETY,

 

 

 

 

FOLLOW THESE INSTRUCTIONS TO SHUT DOWN YOUR HEATER

Keep all flammable objects, liquids and vapors the

 

 

 

 

 

 

 

required clearances to combustibles away from heater.

1. Set the thermostat to off or the lowest setting.

 

 

 

 

 

 

 

2. Turn off electric power to the heater.

 

 

Failure to follow these instructions can result in death,

3. Turn off the manual gas valve in the heater supply line.

injury or property damage.

4. Call your registered installer/contractor qualified in the installation

 

 

 

 

and service of gas-fired heating equipment.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation Clearances

 

 

Clearances to Combustibles

 

 

 

Roof Terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Roof Terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air

 

15 cm

15 cm

 

Intake

 

 

50 cm**

10 cm

Flue

3 m

 

Wall

 

 

Terminal 25 cm

 

30 cm

 

 

 

3 m

 

 

2.5 - 3.5 m*

 

 

 

 

 

 

*Heaters may be mounted at a higher level if destratification fans are installed.

**80 cm is necessary to service heater

 

Roberts-Gordon, LLC

Roberts-Gordon Europe Limited

Service Telephone: +44(0) 1902 498733

 

1250 William Street

Oxford Street

Service Fax: +44(0) 1902 401464

 

 

 

P.O. Box 44

Bilston, West Midlands WV14 7EG UK

E-mail: uksales@rg-inc.com

 

 

 

Buffalo, NY 14240-0044 USA

Telephone: +44(0) 1902 494425

E-mail: export@rg-inc.com

 

 

 

Fax: +44(0) 1902 403200

 

 

 

 

 

Telephone: 716.852.4400

 

 

 

 

 

 

 

 

 

 

 

Fax: 716.852.0854

 

 

 

 

 

 

Toll Free: 800.828.7450

 

 

 

 

 

Installation Code and Annual Inspections: All installations and service of ROBERTS GORDON® products must be performed by a contractor qualified in the installation and service of products sold and supplied by Roberts-Gordon and conform to all requirements set forth in the ROBERTS GORDON® manuals and all applicable governmental authorities pertaining to the installation, service and operation of the equipment. To help facilitate optimum performance and safety, Roberts-Gordon recommends that a qualified contractor annually inspect your ROBERTS GORDON® products and perform service where necessary, using only ROBERTS GORDON® replacement parts.

Further Information: Applications, engineering and detailed guidance on systems design, installation and product performance is available through ROBERTS GORDON® representatives.

Please contact us for any further information you may require, including the Installation, Operation and Service Manual.

This product is not for residential use.

This document is intended to assist licensed professionals in the exercise of their professional judgement.

© 2006 Roberts-Gordon, LLC

All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or by any means – graphic, electronic, or mechanical, including photocopying, recording, taping, or information storage

www.rg-inc.com

and retrieval systems – without written permission of Roberts-Gordon, LLC.

Printed in U.S.A.

 

Page 40
Image 40
Roberts Gorden CTCU 22, CTCU 27, CTCU 15, CTCU 11, CTCU 7 Fire Hazard, close to heater, injury or property damage