38
Yes |
|
|
|
|
| Is there 24 Vac across 24 V | Secure wiring between 24 V |
Verify external wiring |
| Output #8 on control board | |
No | input connection #8 on the No | ||
diagrams, Does the pump |
| relay board? | and 24 V input connection |
turn on? |
| #8 on relay board. | |
|
| ||
|
| Yes |
|
Troubleshooting
ROBERTS GORDON®
Yes
Replace | No | Is the red LED on | |
See Replacement Parts | |||
relay #8 on the relay board Yes | |||
section. |
| lit? | |
|
|
Yes
Is there 120 V at output # 8
on the relay board?
No
Replace
relay board. See
Replacement Parts section.
Refer to the VFD
manufacturer's Installation and Operation Manual to clear error.
Yes
| Is there 120 V into 120 V |
|
Yes | relay in the variable | Yes |
| frequency drive assembly. |
|
| No |
|
| Rectify wiring between |
|
| controller and 120 V relay. |
|
Is there 120 V (230 V for
Is there continuity between output terminals on 120 V relay.
No
Replace 120 V relay. See Replacement Parts section.
Yes
Yes
Flow Chart (continued)
ULTRAVAC™ CONTROLLER INSTALLATION MANUAL
Yes
Is there continuity between VFD terminals 1 and 11?
No
Rectify wiring between 120 V relay and VFD terminals 1 and 11.
Check circuit breaker and
power supply.
No
Is there power (120 V or 230 V) between the rotary disconnect inputs?
Yes
Turn rotary disconnect switch to the ON position. See Section 6.1.
Yes
Is there power (120 V or 230 V) between the rotary disconnect outputs?
Yes | Is the LCD display | Yes | |
of the VFD on? | |||
|
|
No
Is there power (120 V or
230 V) between L1 and Yes L2/N inputs on the VFD?
No
Is there power (120 V or
230 V) between fuse Yes holder outputs?
| No |
|
No | Is there power (120 V or | Yes |
| 230 V) between fuse |
|
| holder inputs? |
|
No | Replace rotary disconnect | |
base block. | ||
|
Is there an error showing
on the LED display?
Replace VFD. See
Replacement Parts
section.
Rectify wiring between fuse
holder outputs and VFD power inputs L1 and L2/N
Replace fuse. See
Replacement Parts
section.
460 V models) between any No two output (motor) terminals No
(U,V or W)? Yes
Is there power between any
two input wires at the No pump?
Yes
Is the pump motor hot? | Yes |
No
Disconnect power to the motor. Does the motor shaft turn freely?
No
Is the pump impeller
obstructed?
No
Motor bearings may have failed. Repace motor.
Replace VFD. See
Replacement Parts
section.
Rectify wiring between
VFD and pump.
Motor may have tripped
overload. Wait