SECTION 4: TYPICAL EXTERNAL DIAGRAMS

SECTION 4: TYPICAL EXTERNAL DIAGRAMS

SECTION 4: TYPICAL EXTERNAL DIAGRAMS

FIGURE 10: Central Controller Communication Equalization Wiring

All ULTRAVAC™ Central Controllers are shipped with a communication equalization cable

(P/N 10080450). The cable is supplied to equalize and balance the circuitry of the communications on the controller network that may be experiencing noise or transient voltage levels. Connect the communi- cation equalization cable as shown below to the first or the last controller on the data bus.

Shrinkwrap

Communications Circuit Equalizer Wiring Manual background (included, must be field installed)

 

 

 

 

 

 

 

 

 

 

BLACK

 

 

 

 

 

 

 

 

 

BLACK

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This connector will plug into the right set of RS-485 +/- terminals on this board as shown.

120 ohm resistor (included w/ P/N 100800450)

OUT IN G

RS232 DIRECT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+32 +5 G G

G

REF

-

+

REF

-

+

-

+

-

+

-

+

-

+

 

 

 

 

OUT

 

 

IN

 

 

 

4

 

 

 

3

 

 

 

2

 

 

 

1

 

 

AUX POWER

 

 

 

RS485 COMM

 

 

 

 

 

 

METER INPUTS

 

 

 

 

 

 

RESET

OH CD RI

ADDRESS

 

 

 

 

 

 

 

 

 

 

 

 

UNIVERSAL INPUTS

 

 

 

 

 

2

 

 

 

 

1

 

 

 

8

 

 

 

7

 

 

6

 

 

 

 

5

 

 

 

 

4

 

 

 

3

 

 

 

 

 

 

 

 

-

+

-

+

 

-

 

+

 

-

+

 

-

+

 

-

+

 

-

 

+

-

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description

Part Number

Comms Equalization Cable

10080450

 

 

CPU

OUT Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background 499 OHM

IN

OFF Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background 10VDC

ON

4

-

+

 

3

-

+

 

2

-

+

 

1

+ -

15

Page 21
Image 21
Roberts Gorden NEMA 4 installation manual Typical External Diagrams