Roberts Gorden Specifications, Standard Enclosure, NEMA 4 Enclosure P/N, Outdoor Sensor P/N

Models: NEMA 4

1 48
Download 48 pages 39.44 Kb
Page 13
Image 13
SECTION 2: SPECIFICATIONS

SECTION 2: SPECIFICATIONS

SECTION 2: SPECIFICATIONS

2.1ROBERTS GORDON® ULTRAVAC™ Controller 2.1.1 Enclosure

Standard Enclosure

Construction: 16 gauge painted steel, hinged door, removable knockouts provided.

Dimensions: 14.7" w x 17.7" h x 3.5" d

NEMA 4 Enclosure (P/N 10080302)

Description: NEMA 4 enclosure is sold separately as an option. ULTRAVAC™ Controller in standard enclosure is field mounted inside the NEMA 4 enclosure.

Construction: 14 gauge painted steel, hinged door with 19" x 16" window.

Dimensions:

24" w x 24" h x 9" d

Protection

 

Rating:

NEMA 4/12

2.1.2 Electrical - Control Board

Power Supply: 24 V 60 Hz (from relay board)

Analog Inputs: Sensor (thermistor), BMS enable (dry contact)

Relay Outputs: 24 Vac

Analog Outputs: 0-10 Vdc

Digital Inputs: Timed, dry contact

Network Ports: RS-485, RS-232

UL Standard: UL 916 / C22.2 No. 205-M1983

2.1.3 Electrical - Relay Board

Power Supply: 120 V (+/- 10%) 1 Ø, 60 Hz

Inputs:

24V AC

Relay Outputs: Single Pole 3 A 120 Vac

UL Standard: UL 916 / C22.2 No. 205-M1983

2.2Temperature Sensors Indoor Sensor

Dimensions:

2.75" w x 4.5" h x 1.15" d

Power:

32 V DC

Features:

LCD temperature display, setpoint

 

adjustment, override button

Wiring:

Shielded Cable, four twisted pairs,

 

24 AWG min.

Outdoor Sensor (P/N 10081501)

Dimensions:

1.4" w x 5.3" h x 2" d

Enclosure:

NEMA 4 gasketed aluminum LB

 

housing, ½" threaded connection

Wiring:

Shielded Cable, one twisted pair,

 

22 AWG min.

NEMA 4 Enclosure for Indoor Sensor (P/N 10081510)

Description:

NEMA 4 Enclosure is sold separately

 

as an option. The indoor sensor is

 

field mounted inside the NEMA 4

 

enclosure. Temperature thermistor

 

and LCD temperature display will not

 

operate properly inside the

 

enclosure. LCD display feature should

 

be disabled and use of the NEMA 4

 

sensor enclosure will require the use

 

of an outdoor sensor (P/N 10081501)

 

in the space to monitor zone

 

temperature.

Dimensions:

6.3" x 3.6" x 1.8"

Construction: Polycarbonate enclosure with clear

 

front cover, 4 screw cover closure. 16

 

gauge galvanized subpanel.

Protection

 

Rating:

NEMA 4/4x/12/13

Flammability

 

Rating:

UL-94-5V

7

Page 13
Image 13
Roberts Gorden Specifications, Standard Enclosure, NEMA 4 Enclosure P/N, Electrical - Control Board, Outdoor Sensor P/N