Connecting to MIDI Devices

Cautions when Connecting an External MIDI Device

Here we will explain the “Local On/Off” and “Omni On/ Off” settings that you need to be aware of when connecting the F-100 to an external MIDI device.

Disconnecting the F-100’s keyboard and internal sound

generator (Local On/Off)

When the F-100 is connected to a MIDI sequencer or the like, set it to Local Off.

As shown in the diagram, the data that is produced when you play the keyboard will reach the sound generator by two routes, (1) and (2), causing each note to be played in duplicate. To prevent this, select the Local Off setting to cut route (1).

fig.8-04.e

(1) Local On

 

 

Sequencer

Sound

MIDI

MIDI

IN

OUT

Generator

 

Memory

 

 

 

MIDI

MIDI

 

OUT

IN

(2) Thru function On Each note played

is sounded twice

This sets it to Local On:

fig.8-05.e

Sound is emitted

Sound Generator

Local On

This sets it to Local Off:

fig.8-06.e

No sound produced

Sound Generator

Local Off

NOTE

Be aware that if you set your instrument to Local Off when no external MIDI device is connected, there will be no sound.

Switching Local On/Off

Local On is set when the power is switched on.

1.While holding down the [Variation] button and [Song] button, the “C8” note to turn the setting

On, or press the “B7” note to turn the setting Off.

fig.8-07.e

VariationSong

Dual Balance

Key Touch

Power

Local Off

Local On

If the F-100 is connected to a Roland MT series (except MT- 90s), it is not necessary to make the Local Off setting. When the power is turned on, the MT series will transmit a Local Off message. If you turn the power on in the order of first the F-100 and then the MT series, the F-100 will automatically be set to Local Off.

Receiving on all MIDI channels

(Omni On/Off)

When set to Omni On, the F-100 will sound as a result of received MIDI messages, no matter which channel the messages arrive on.

When set to Omni Off, the F-100 will recognize only the messages that arrive on the MIDI channel that has been selected, as explained under “Set the MIDI Channel.”

Switching Omni On/Off

Omni On is automatically set when the power is switched on.

1.Hold down the [Variation] button and [Song] button, and press the “A7” note to turn the setting

On, or the “G7” note to turn the setting Off.

fig.8-08.e

VariationSong

Dual Balance

Key Touch

Power

Omni Off

Omni On

31

Page 31
Image 31
Roland F-100 owner manual Switching Local On/Off, Receiving on all Midi channels Omni On/Off, Switching Omni On/Off