34
CARETAKER PLUS INSTALLATION AND OPERATIONS MANUAL
Appendix D: Factory Defaults
Upon receiving the Caretaker Plus from the factory, or restoring the unit to default
parameters (see 'RESTORE TO DEFAULT FUNCTION'),
The factory default settings are:
Timeout: 20 seconds
Protocol Serial: 9600 baud, no parity, 8 bits, 1 stop, DTR flow control
Protocol Parallel: Use busy and acknowledge
Form Feed: Off
Initialization String: None
Unidirectional X-on/X-off: Yes
Parallel Enable Logic: Yes
Reverse Channel Data Timeout: No
Flow Timeout on Busy (Ports 1-8): Yes
Filter Size: O characters
Appendix E: General Specifications
Serial Models
Electrical: RS232 -9 to +9 volts
Protocol: Asynchronous; DTR/DSR, X-on/X-off flow control
Baud Rate: 50-19200 baud
Word Length: 5, 6. 7, or 8
Parity: odd, even, mark, space, or none
Stop bits: 1 or 2
Parallel Models
Electrical: TTL levels
protocol Centronics compatible STBIACWBUSY interface
Size and Weight
10.5" wide X 3.5" high X 5.0" deep 5 ports: 7 Ibs 9 ports: 8 Ibs
Chassis
Steel tan painted enclosure, rear mounted connectors
Aluminum black anodized 5.25" X 19" rack mount (optional)
Power
110 volt, 10 VA external wall mount adapter (standard)
220 volt, 10 VA external floor mount adapter (optional)
110 volt, 10 VA external floor mount adapter (optional)
Display
Port status LEDS: 1-8
Unit status LEDs: Power, Mode, Data, Busy, Error
Environment
0-70 degrees C., 0-95% relative humidity
Connectors
Serial: DB25 female
Parallel: Centronics 36 female or DB25 female
Warranty
1 year parts and labor. Extended warranty available