CPU 2 | CPU 1 |
UltraView Pro 8 port |
|
CPUs
KVM station
(4 CPUs can be connected using a
Figure 3. UltraView Pro to CPUs
Installation - Cascading units
The UltraView Pro units can be cascaded together to expand the number of computers that can be accessed from the KVM station.
When cascading units, one unit becomes the “Master” unit and all others are “Slave” units. Each computer port on the master unit can be connected to a slaves KVM connector. Figure 4 illustrates the addition of two
The UltraView Pro must be configured to properly manage the cascaded units. The maximum number of computers, the number of slave units connected, and the number of ports (width) on each slave unit must be entered into the menu system and saved. In the example in Figure 4, the maximum computer entry would be 22, the number of slave units is 2, and the number of ports on each slave unit would be 8. It is recommended that all slave units have the same number of computer ports.
It is only necessary for the “Master” unit to be equipped with an OSD. Slave units can be an UltraView or ServeView product without an OSD. All units should have the same or latest firmware revision.
10ULTRAVIEW PRO INSTALLATION AND OPERATIONS MANUAL