Up to 8 UltraView Pro

 

SLAVE #2

Slaves can be connected*

SLAVE #1

CPUs 9-16

CPUs 1-8

MASTER

CPUs 17-22

KVM station

* 4 units can be cascaded using a 4-port master/16 using a 16-port master

Figure 4. Cascading units

Slave unit installation

To properly install the slave units, follow the below steps.

(See the Configure System menu section for detailed instructions)

1.Connect the KVM stations keyboard, monitor, and mouse to the master units Monitor/Keyboard/Mouse connector using the appropriate KVM cable.

2.Connect CPU port #1 on the master unit to the KVM connector on Slave #1 using a DB25 to DB25 expansion cable.

(Rose Electronics part number CAB-CXVSMMnnn)

3.Connect the next sequential CPU port on the master unit to the KVM connector on the next sequential Slave unit.

4.Connect the remaining Slave units to the master unit.

5.When all slave units are connected, call up the UltraView Pro’s “Main configuration” menu by pressing and releasing the left control <Ctrl> key, then the F12 key. (See Figure 5).

6.Using the up/down arrow keys, select (highlight) “Configure system” and press enter. The “Configure system” menu will display. (See Figure 6)

7.Using the up/down arrow keys, select “Maximum computers” and press enter. Enter the total possible number of computers in the system and press enter.

ULTRAVIEW PRO INSTALLATION AND OPERATIONS MANUAL